Resideo L8100B1128 High-Limit Aquastat W/Dual Bulb, 200°F Limit 39" Capillary

Special Price $357.15 Regular Price $396.44
Out of stock
SKU
L8100B1128
The Resideo L8100B1128 High-Limit Aquastat with Dual Bulb is an immersion-type controller that is used to control and limit the temperature of the tank in water heaters. working temperature of this aquastat is from 100°F to 180°F the device is crucial in the process of heating water to the right temperatures. Temperature sensing is made better by the dual-bulb design and the high-limit to ensure that water does not heat beyond 200°F. The Resideo L8100B1128 comes with 39” capillary length and 3/8” bulb diameter and is quite easy to install and quite compatible with most HVAC equipment especially in residential and commercial water heating systems.
https://www.partshnc.com/media/catalog/product/l/8/l8100b1128-resideo_partshnc.jpg

Specifications

  • Application: Immersion type controllers for regulating and limiting the tank temperature in water heaters
  • Capillary Length: 39"
  • Temperature Range: 100°F to 180°F
  • Differential Temperature: 5°F
  • Bulb Diameter: 3/8"

Product Overview:
Monitors and limits temperature in a heating system to support high-limit temperature control. The Resideo L8100B1128 High-Limit Aquastat is an OEM temperature-control component featuring a 100°F–180°F temperature range, a 3/8-inch sensing bulb, and a 39-inch capillary. Its remote bulb configuration supports temperature sensing at the designated location for heating equipment requiring the specified control range and sensing arrangement.

Temperature Monitoring:
The aquastat responds to temperature conditions detected by its dual-bulb sensing arrangement. The sensing bulbs connect to the control through the specified 39-inch capillary, allowing the temperature-sensing assembly to provide a temperature-based control response within the corresponding water-heating application. The 3/8-inch bulb diameter is part of the specified sensing configuration.

High-Limit Control:
Within a water heater, the aquastat provides temperature-based control associated with regulating and limiting tank temperature. Its specified differential temperature is 5°F, which identifies the temperature difference associated with the control operation. The aquastat functions as part of the water heater's temperature-control system rather than as a heat-generating component.

Replacement Guidelines:
Replace the Resideo L8100B1128 High-Limit aquastat if it fails to respond at the required temperature, shows physical damage, or has damage to the capillary or sensing bulbs. A replacement should match the required sensing configuration, capillary length, bulb diameter, temperature-control characteristics, electrical requirements, mounting arrangement, and water-heating application.

Common Failure Symptoms:

  • Failure to respond at the specified temperature limit.
  • Inconsistent temperature-based control operation.
  • Damage to the capillary tube or sensing bulbs.
  • Visible corrosion or physical damage to the control housing.
  • Connected water-heating equipment operating outside its expected temperature range.

Equipment Compatibility:
The Resideo L8100B1128 is specified for water heaters requiring an immersion-type high-limit aquastat with a dual-bulb sensing arrangement. Verify the existing control's sensing configuration, temperature requirements, capillary length, bulb dimensions, and applicable equipment model before purchasing.

Technical Specifications:
Brand: Resideo
Part Number: L8100B1128
Product Type: High-Limit Aquastat
Temperature Range: 100°F–180°F
Bulb Diameter: 3/8 in.
Capillary Length: 39 in.

Write Your Own Review
You're reviewing:Resideo L8100B1128 High-Limit Aquastat W/Dual Bulb, 200°F Limit 39" Capillary
Your Rating
Customer Questions
What is the Resideo L8100B1128 aquastat used for?

The L8100B1128 is an immersion-type high-limit aquastat designed to regulate and limit tank temperature in applicable water heaters.

What should I verify before selecting the L8100B1128 aquastat?

Check the existing control part number, water-heater requirements, sensing-bulb arrangement, and installation specifications against the manufacturer's documentation.

What can cause a water heater's high-limit control to interrupt heating unexpectedly?

Excessive water temperature, a sensing problem, or a fault elsewhere in the heating system may cause an interruption and require professional diagnosis.

When should the L8100B1128 aquastat be replaced?

Consider replacement if the control is damaged or fails to regulate the water-heater temperature as specified after appropriate troubleshooting.

What maintenance is appropriate for a high-limit aquastat?

During scheduled water-heater servicing, have a qualified technician check the control, capillary, sensing bulbs, and electrical connections for visible damage or deterioration.