Facebook Pixel

Resideo L6008A1242 Adjustable Differential Circulator Aquastat High/Low Limit 100°F-200°F

Special Price $311.99 Regular Price $346.31
In stock
SKU
L6008A1242
The Resideo L6008A1242 Circulator Aquastat is a versatile control unit that controls and measures the temperature of heating systems with particular emphasis on circulators. This aquastat is essentialin ensuring that temperatures are well regulated and more importantly, ensuring that heating systems are safe since it has both high and low settings. The temperature control of the heating operation varies between 1000F and 2000F which is adjustable to suit the heating process. The 96 capillary length and copper bulb provide the better temperature sensing and ensure that the device will perform consistently. This aquastat is commonly used in different HVAC systems such as hydronic heating and circulator pumps.
https://www.partshnc.com/media/catalog/product/l/6/l6008a1242.jpg

Specifications

  • Application: Circulator Control and High Limit or Low Limit
  • Capillary Length: 96"
  • Operating Temperature: 100°F to 200°F
  • Bulb Material: Copper

Product Overview:
Monitors water temperature and coordinates circulator operation in hydronic heating systems through adjustable high- and low-limit controls. The Resideo L6008A1242 Adjustable Differential Circulator Aquastat High/Low Limit 100°F-200°F is an OEM temperature-control component designed for applications requiring circulator switching and adjustable temperature thresholds. Its 100°F–200°F operating range supports temperature-based control according to the heating system's requirements.

Circulator Control:
Coordinates the electrical switching sequence associated with the system circulator. The control responds at the designated operating points and changes the circuit state as required by the established control settings. This function focuses on the electrical coordination of the circulator rather than describing the general temperature-monitoring role of the aquastat.

Low-Limit Control:
Establishes a lower operating boundary within the control arrangement to maintain the selected minimum condition. The low-limit setting provides a defined reference for the associated switching circuit and helps govern system response when the monitored condition approaches that boundary. This function specifically concerns the lower control threshold.

Replacement Guidelines:
Replaces the Resideo L6008A1242 Adjustable Differential Circulator Aquastat High/Low Limit 100°F-200°F when the existing aquastat no longer provides the required temperature control or differential switching. Renew the control when sensing or switching performance becomes inconsistent.

Common Failure Symptoms:

  • Circulator remains energized beyond the intended limit.
  • High-limit cutoff occurs before the expected temperature.
  • Low-limit setting fails to maintain the selected threshold.
  • Temperature differential does not match the selected setting.
  • Aquastat response fluctuates around the control range.

Equipment Compatibility:
The Resideo L6008A1242 Adjustable Differential Circulator Aquastat High/Low Limit 100°F-200°F is intended for hydronic heating equipment requiring adjustable high/low temperature limits and circulator control. Its application depends on the associated temperature-control arrangement and circulator circuit. Verify the L6008A1242 equipment model and manufacturer's parts documentation before ordering.

Technical Specifications:
Brand: Resideo
SKU: L6008A1242
Product Type: Circulator Aquastat
Control Type: High/Low Limit
Temperature Range: 100°F-200°F
Feature: Adjustable

Write Your Own Review
You're reviewing:Resideo L6008A1242 Adjustable Differential Circulator Aquastat High/Low Limit 100°F-200°F
Your Rating
Customer Questions
Where is the Honeywell L6008A1242 temperature control used?

It provides adjustable temperature-based switching for applicable hydronic heating systems.

Why choose the OEM L6008A1242 control?

Verify the part number, temperature requirements, and electrical specifications against manufacturer documentation. Confirm OEM status before listing it as an OEM part.

What symptoms may indicate a faulty hydronic temperature control?

Unexpected heating operation or a circulator that fails to respond correctly may indicate a control or system issue.

When should the L6008A1242 control be replaced?

Consider replacement if the control is damaged or fails to switch correctly after appropriate troubleshooting.

What maintenance helps keep the temperature control operating reliably?

Have a qualified technician inspect the control, wiring, and electrical connections for wear or damage during scheduled servicing.