Facebook Pixel

Resideo L4029E1219 Fixed Limit Controller 165°F 3" Insert

Special Price $193.07 Regular Price $222.03
In stock
SKU
L4029E1219
The Resideo L4029E1219 Limit Controller is an alarm system that is intended to prevent water heaters and boilers from overheating. It also serves as a temperature monitor or a temperature sentinel that halts the system when the temperature goes up to 165°F. It includes a 3-inch insert and is easy to install in the HVAC system. This limit controller is essential in preventing various risks, for instance, damaging of equipment or fire resulting from high temperatures. After enabled, it needs to be reset to guarantee purposeful activity before the system’s restart. The controller’s gives provision for installation in different places. Adding this element into your water heater or boiler can greatly enhance safety and reliability of the system.
https://www.partshnc.com/media/catalog/product/l/4/l4029e1219-resideo_partshnc.jpg

Specifications

  • Type: Limit Controller
  • Temperature: 165°F
  • Pipe DIA: 3"
  • Differential Temperature: 25°F
  • Dimensions: 3.75" X 2" X 2.31"
  • Reset Type: Manual
  • Applications: Water Heaters & Boilers

Product Overview:
Monitors temperature conditions and initiates electrical switching when the specified high-limit threshold is reached. The Resideo L4029E1219 SPST High Limit Reset Control N/C 3" Insert Length 165°F Manual Reset is an OEM temperature-safety control component featuring normally closed (N/C) contacts, a 3-inch insert length, and a 165°F limit setting. Its manual-reset design requires deliberate resetting following a high-limit condition.

Temperature-Responsive Switching:
Temperature-sensitive control operation allows the device to respond to changes in the sensed temperature and initiate the appropriate electrical switching action. This type of control uses temperature response as the basis for changing the state of the connected circuit when the defined limit condition is reached.

High-Limit Control Within Equipment Operation:
Within an HVAC operating cycle, the control provides temperature-limit switching that interacts with the associated electrical control circuit. Its temperature-responsive action allows the equipment's control arrangement to respond when the sensed condition reaches the defined limit, while the reset characteristic supports controlled return to normal operation.

Replacement Guidelines:
When selecting a control for an existing HVAC application, the switching arrangement, temperature response, sensing configuration, and reset characteristics should correspond with the equipment requirements. The Resideo L4029E1219 SPST High Limit Reset Control N/C 3" Insert Length 165°F Manual Reset provides the specific configuration described by the product data and should be matched with the control requirements of the applicable equipment.

Common Failure Symptoms:

  • High-limit switching may become inconsistent during equipment operation.
  • The control may respond irregularly to the applicable temperature condition.
  • Circuit interruption may occur at an unexpected point in the operating cycle.
  • The reset response may become inconsistent following a high-limit condition.
  • Temperature-limit control behavior may differ from the expected equipment sequence.

Equipment Compatibility:
Resideo L4029E1219 SPST High Limit Reset Control N/C 3" Insert Length 165°F Manual Reset is intended for HVAC equipment applications requiring the specified high-limit control arrangement. The applicable equipment should have requirements that correspond with the control's listed configuration and temperature-control characteristics.

Technical Specifications:
Brand: Resideo
SKU / Part Number: L4029E1219
Control Type: SPST High Limit Reset Control
Contact Configuration: N/C
Insert Length: 3"
Temperature: 165°F
Reset Type: Manual Reset

Write Your Own Review
You're reviewing:Resideo L4029E1219 Fixed Limit Controller 165°F 3" Insert
Your Rating
Customer Questions
What is the Resideo L4029E1219 high-limit control used for?

It monitors temperature and changes the associated electrical circuit state when the specified high-limit condition is reached.

What does the normally closed (N/C) contact arrangement mean?

The contacts remain closed under normal conditions and open when the applicable high-limit condition triggers the control.

Why does the L4029E1219 use a manual reset?

Manual reset requires deliberate restoration after the high-limit condition has been addressed, rather than automatically returning the control to its normal state.

What temperature setting is specified for the L4029E1219?

It has a specified temperature setting of 165°F for the applicable high-limit control application.

How should the L4029E1219 high-limit control be maintained?

Inspect the control, sensing arrangement, and electrical connections for damage or loose wiring. Have a qualified technician verify temperature response and reset operation according to manufacturer guidance.