The Resideo L4029E1011 Limit Control is a reliable fixed-temperature safety device optimal performance and protection of HVAC systems. This limit control is an essential component for warm air and air conditioning systems because it has a manual reset and is set at 135°F. The working of the device is to keep a check on the system temperature and as soon as the temperature crosses the set limit of 135°F the high limit cutout is activated.It helps in avoiding overheating that can damage the system or pose a danger to wellbeing is regularly used in heating, ventilation and air conditioning units for houses as well as commercial buildings where it is advisable to achieve appropriate working temperatures.
https://www.partshnc.com/media/catalog/product/l/4/l4029e1011.jpg

Specifications

  • Application: Provides high limit cutout with manual reset in warm air or air conditioning systems
  • Height: 3.75"
  • Width: 2.31"
  • Color: Gray
  • Temperature: 135°F
  • Type: Limit Control
  • Element Insertion Length: 3"
  • Switch Type: Normally Closed SPST
  • Reset Type: Manual Reset

Product Overview:
Monitors air temperature and interrupts the associated electrical circuit when the temperature reaches its fixed 135°F limit. The Resideo L4029E1011 Limit Control Manual Reset 135°F Fixed is an OEM HVAC safety control featuring a bimetal sensing element, SPST switching, and manual reset operation. It supports high-temperature protection in air-conditioning, ventilating, and warm-air heating equipment.

Thermal Protection:
Safeguards the associated equipment circuit when monitored temperature reaches the established limit. At the designated threshold, the control changes its electrical state to interrupt the connected circuit and limit continued operation under elevated-temperature conditions. Manual reset provides a deliberate means of returning the control to its operating state after the temperature condition has been addressed.

Temperature Sensing:
Uses a bimetal sensing element to respond to changes in surrounding air temperature. Thermal changes at the sensing location cause the element to move mechanically and actuate the internal switch mechanism. Positioning the sensing element within the airstream allows direct response to monitored air temperature, providing the mechanical movement required for temperature-based switching.

Replacement Guidelines:
Replace the Resideo L4029E1011 M/R Limit Control 135°F Fixed when the existing limit control has deteriorated, has been removed during service, or no longer provides adequate temperature-limiting control. Renew the control during applicable maintenance or component replacement to restore the required limit-control function and support proper equipment operation.

Common Failure Symptoms:

  • Inconsistent temperature-limit response
  • Circuit remaining open after the temperature condition has cleared
  • Physical deterioration of the control
  • Irregular response to rising air temperature
  • Failure to provide the expected limit-control action

Equipment Compatibility:
The Resideo L4029E1011 M/R Limit Control is designed for corresponding air-conditioning, ventilating, and warm-air heating applications that require temperature-based limit control. Application may vary according to the equipment configuration and control arrangement. Always verify the L4029E1011 equipment model, existing control arrangement, and applicable parts documentation before selecting this control.

Technical Specifications:
Brand: Resideo
Part Number: L4029E1011
Product Type: Limit Control
Reset Type: Manual
Temperature: 135°F Fixed
Switch Type: SPST
Reset Type: Manual

Write Your Own Review
You're reviewing:Resideo L4029E1011 M/R Limit Control 135°F Fixed
Your Rating
Customer Questions
What is the Resideo L4029E1011 limit control used for?

It monitors temperature and changes the control state when the specified limit is reached.

Why do heating systems use a fixed temperature limit?

It provides a predetermined temperature threshold for controlling equipment operation.

Can the L4029E1011 temperature setting be adjusted?

No. It uses a fixed temperature limit rather than an adjustable setting.

What signs may indicate a faulty limit control?

Unexpected switching, failure to respond to temperature changes, or irregular equipment operation may indicate a problem.

How should a fixed limit control be inspected?

Check for physical damage and loose connections. Have a qualified technician test its operation according to the manufacturer's service instructions.