The Resideo L4008E1313 High Limit Aquastat is a temperature control device designed for use in hydronic heating systems as well as other heating and cooling systems. The remote bulb and the copper bulb of this aquastat have a 66" capillary tube that makes it possible to monitor and control the temperature effectively. It operates between 100°C and 200°C, providing a consistent high-limit safeguard against heat and ensuring safe functionality. If any harm to the system occurs or its durability gets diminished, the heat produced in the fluid will not be too high. In this way, its temperature will always be monitored and controlled through a heating element that will connect with it only after crossing a predefined limit.
https://www.partshnc.com/media/catalog/product/l/4/l4008e1313-resideo_partshnc.jpg

Specifications

  • Color: Gray
  • Capillary Length: 66"
  • Bulb Material: Copper
  • Temperature Range: 100°F-200°F

Product Overview:
The high-limit aquastat regulates temperature within a heating system by monitoring temperature through its remote sensing bulb. The Resideo L4008E1313 High Limit Aquastat is an OEM temperature-control component featuring a 100°F–200°F temperature range and a 66-inch capillary. Its remote-bulb configuration supports temperature sensing at a designated location, while its high-limit function helps regulate the heating system within the specified temperature range.

High-Limit Switching:
Provides a defined switching response when the monitored temperature reaches the selected high-limit setting. The control uses the temperature detected by its remote sensing element to determine when the switch should change state. Its manual-reset arrangement maintains the high-limit control function until the appropriate reset action is taken. This makes the switching function directly responsive to the temperature condition detected at the sensing location.

Temperature-Based Control:
Uses sensed temperature as the input for controlling the connected heating circuit. The remote bulb detects the temperature at the selected sensing point and transfers that condition through the capillary to the control mechanism. The control then responds according to its configured temperature setting, allowing temperature conditions to determine the associated switching action.

Replacement Guidelines:
Replace the aquastat when the existing control shows signs of wear or damage or when its temperature control response is no longer suitable for the application. Before ordering, verify the L4008E1313 part number, high-limit aquastat configuration, remote bulb arrangement, and applicable heating system requirements. Confirm the equipment model number, existing component identification, and manufacturer's parts documentation to ensure the selected aquastat matches the system requirements.

Common Failure Symptoms:

  • High-limit control does not respond as expected to a temperature condition.
  • Equipment operation is interrupted by inconsistent temperature-limit behavior.
  • Control does not maintain its intended manual-reset function.
  • Temperature-limiting behavior does not correspond with the selected setting.
  • Damage to the remote sensing assembly is visible or affects temperature-control operation.

Equipment Compatibility:
The Resideo L4008E1313 High Limit Aquastat Remote Bulb supplied product title identifies this component as a high-limit aquastat with a remote bulb. Before purchase, the application should be matched against the required high-limit function, manual-reset configuration, 100°F to 200°F temperature range, and 66-inch capillary specification.

Technical Specifications:
Brand: Resideo
Part Number: L4008E1313
Component Type: High Limit Aquastat
Sensing Configuration: Remote Bulb
Temperature Range: 100°F to 200°F
Capillary Length: 66 inches

Write Your Own Review
You're reviewing:Resideo L4008E1313 High Limit Aquastat Remote Bulb M/R 66" Capillary 100°-200°F
Your Rating
Customer Questions
Which heating systems use the Honeywell L4008E1313 Aquastat?

The L4008E1313 is designed for compatible boilers, tanks, and other hydronic heating applications requiring high-limit temperature control. Verify the equipment model and control requirements before ordering.

Why choose the OEM L4008E1313 Aquastat control?

An OEM control is specified for its intended equipment application. Confirm the part number, temperature-control requirements, and manufacturer documentation to ensure the correct replacement is selected.

What happens when the L4008E1313 reaches its high-limit setting?

Its manual-reset feature requires manual intervention to reset the control after the high-limit switching function has been triggered. Follow the equipment manufacturer's reset and safety procedures.

How does the remote sensing bulb regulate temperature monitoring?

The sensing bulb detects temperature at the selected location and transfers that condition to the control through a capillary tube, supporting remote temperature sensing.

What maintenance checks help keep the Aquastat operating properly?

Have a qualified technician inspect the sensing bulb, capillary tube, electrical connections, and control operation during scheduled servicing. Address damaged components or abnormal temperature-control behavior promptly.