Facebook Pixel

Resideo L4008E1305 High-Limit Aquastat Manual Reset Remote Bulb 100°F/240°F 5.5ft Capillary

Special Price $271.84 Regular Price $301.74
In stock
SKU
L4008E1305
The Resideo L4008E1305 Limit Aquastat is a Heating and Cooling Control Limit that provides high limits of temperature control in Heating and Cooling applications. It has a manual reset button and requires a power supply of 120V. The unit also has a 3/8" capillary remote bulb which is used to measure the temperature of the system. When the temperature rises high the switch which is an SPST type opens and needs to be closed manually to avoid overheating. It is copper-made and is ideal for safeguarding several heating systems including boilers and water heaters against overheating.
https://www.partshnc.com/media/catalog/product/l/4/l4008e1305.jpg

Specifications

  • Application: High Limit
  • Size: 3/8"
  • Manual Reset
  • Voltage: 120V
  • Power: 8A
  • Switch Type: SPST
  • Material: Copper
  • Changeover: Manual

Product Overview:
Monitors liquid temperature in boilers or tanks and interrupts the associated control circuit when the high-limit setting is reached. The Resideo L4008E1305 High-Limit Aquastat Manual Reset Remote Bulb 100°F–240°F 5.5' Capillary is an OEM temperature-safety control component featuring a 100°F–240°F operating range, manual reset, and remote bulb sensing. Its 66-inch capillary connects the sensing bulb to the switching mechanism, which uses SPST contacts that open as temperature rises to the limit.

Temperature Switching:
The remote bulb responds to temperature changes at the sensing location and transfers the thermal response through the capillary to the Aquastat switching mechanism. When the sensed temperature reaches the selected high-limit setting, the SPST snap-acting contacts break on temperature rise. The controller provides a 100°F to 240°F operating range, with a factory-set stop at 240°F. This sensing and switching arrangement allows the control to respond to the temperature condition detected by its remote bulb.

High-Limit Control Function:
Within a boiler or tank heating cycle, the Aquastat serves as the high-limit control in the associated temperature-control circuit. When the monitored temperature reaches the selected limit, the contacts open and interrupt the associated circuit. Its manual-reset configuration keeps the limit condition from automatically returning to normal operation; the controlled temperature must fall 20°F below the set point before the contacts can be manually reset. This configuration distinguishes the controller from continuously cycling temperature controls.

Replacement Guidelines:
Replacement should be considered when the existing Resideo L4008E1305 high-limit Aquastat no longer provides the specified temperature-limit switching function or when its sensing assembly or control characteristics no longer correspond with equipment requirements. Selection should account for the required temperature range, manual-reset function, switching action, and remote capillary length.

Common Failure Symptoms:

  • Failure to interrupt the associated circuit when the specified high-limit temperature is reached.
  • Unexpected interruption of the heating control circuit during normal operation.
  • Visible damage to the remote sensing bulb or capillary.
  • Abnormal response from the high-limit temperature-control circuit.
  • Inability of the controller to provide the specified temperature-limit switching function.

Equipment Compatibility:
The L4008E1305 is specified for limiting or regulating liquid temperature in boilers or tanks and can also be used for duct or outside-air temperature sensing. The controller has a 100°F to 240°F operating range, manual-reset high-limit function, SPST contacts that break on temperature rise, and a 66-inch capillary. Before purchasing, verify the equipment model number, manufacturer documentation, existing Aquastat identification, and any applicable replacement or superseded part numbers to confirm that the control characteristics correspond with the equipment requirements.

Technical Specifications:
Brand: Resideo
Part Number: L4008E1305/U
Product Type: High-Limit Aquastat Controller
Application: High Limit; Manual Reset
Reset Action: Manual Reset

Write Your Own Review
You're reviewing:Resideo L4008E1305 High-Limit Aquastat Manual Reset Remote Bulb 100°F/240°F 5.5ft Capillary
Your Rating
Customer Questions
What is the Resideo L4008E1305 Aquastat used for?

It provides high-limit temperature control for applicable heating systems, with a manual-reset function.

How does the remote sensing arrangement work?

A sensing bulb and capillary transmit the temperature response from the monitored location to the control mechanism.

What does the manual-reset feature do?

It requires manual restoration after the control activates at its high-limit condition, rather than automatically returning to normal operation.

How does the high-limit function protect the heating system?

It changes the electrical switching state when the monitored temperature reaches the configured upper limit, helping control the heating equipment.

How should the L4008E1305 Aquastat be maintained?

Inspect the sensing bulb, capillary, wiring, and connections for damage or deterioration. Have a qualified technician verify temperature response, switching, and manual-reset operation according to manufacturer guidance.