Facebook Pixel

Resideo L4006A1009 High-Low Limit Aquastat Controller 100°F-240°F

Special Price $251.19 Regular Price $278.82
Out of stock
SKU
L4006A1009
The Resideo L4006A1009 High-Low Limit Aquastat Controller constantly monitors the temperature of water flowing in an HVAC system. By compensating for both maximum and minimum temperatures, the controller keeps the system operating within a tight range. When the system detects an increase in the water temperature above the high limit, the system automatically initiates a safety action or shutdown to prevent the system from overheating and causing destructive effects. Upon the temperatures falling below the low limit, immediately shutters on to reheat the system and maintain the desired temperature. With this dual high and low temperature protection, the controller ensures a safe and efficient running of the system without any condition that may damage it or its efficiency.
https://www.partshnc.com/media/catalog/product/l/4/l4006a1009_resideo_partshnc.jpg

Specifications

  • Bulb Size: 3/8" × 2-7/8"
  • Mounting Type: Horizontal/Vertical
  • Capillary Length: 1-1/2"
  • Differential Temperature: 5°F Fixed
  • Temperature: 100°F to 240°F
  • Application: High or Low Limit Control

PRODUCT OVERVIEW:
Provides reliable temperature monitoring and high/low limit control for compatible boiler and hydronic heating systems. The Resideo L4006A1009 SPST Limit Aquastat Controller is an OEM replacement component designed for selected heating equipment requiring a 100°F–240°F temperature control range. Its SPST switching configuration and 1/2-inch NPT connection support temperature-responsive control of the connected heating circuit.

TEMPERATURE RISE:
Responds to changing liquid temperature through a sensing arrangement that reacts as the monitored condition approaches the selected control setting. When the applicable temperature point is reached, the controller changes the state of its electrical contacts to provide the corresponding control response.

HEATING OPERATION:
During heating operation, the controller monitors liquid temperature in relation to the selected high and low control points. Changes in the monitored temperature cause the electrical contacts to interact with the associated heating control circuit according to the established settings. The high-low arrangement connects liquid temperature conditions with changes in the heating control sequence.

REPLACEMENT GUIDELINES:
Replace the Resideo L4006A1009 Aquastat Controller when control failure or damage prevents accurate temperature monitoring or proper SPST switching. Replacement may also be necessary when the heating system operates outside its intended temperature limits or the controller fails to respond consistently to temperature changes. A qualified technician should disconnect power, inspect the electrical wiring and sensing installation, and verify the control operation and connections after replacement.

COMMON SIGNS OF WEAR:

  • Inconsistent high- or low-temperature limit control.
  • Irregular electrical contact switching.
  • Delayed response to changing liquid temperature.
  • Intermittent heating control operation.
  • Temperature control that does not consistently correspond with the selected settings.

EQUIPMENT COMPATIBILITY:
The Resideo L4006A1009 is an OEM replacement component intended for compatible boiler and hydronic heating systems requiring an SPST high/low limit aquastat controller with a 100°F–240°F range. Before purchasing, verify the part number, exact equipment model, switching configuration, temperature range, 1/2-inch NPT connection, mounting dimensions, capillary arrangement, and manufacturer parts documentation.

TECHNICAL SPECIFICATIONS:
Brand: Resideo
Part Number: L4006A1009
Product Type: High-Low Limit Aquastat Controller
Temperature Range: 100°F-240°F
Differential: Fixed

Write Your Own Review
You're reviewing:Resideo L4006A1009 High-Low Limit Aquastat Controller 100°F-240°F
Your Rating
Customer Questions
What is the function of the Resideo L4006A1009 High/Low Limit Aquastat Controller?

It monitors liquid temperature in compatible boiler and hydronic heating systems and operates its electrical contacts according to the selected high- or low-temperature control setting.

How does the Resideo L4006A1009 respond to rising liquid temperature?

Its sensing mechanism responds as liquid temperature approaches the selected control point. When the applicable temperature setting is reached, the SPST contacts change state to provide the corresponding control response.

What is the purpose of the high/low limit control in the Resideo L4006A1009?

The high/low limit arrangement monitors liquid temperature against the selected control points and coordinates electrical switching with the connected heating circuit as temperature conditions change.

How can I verify whether the Resideo L4006A1009 is compatible with my heating equipment?

Confirm that your system requires an SPST high/low limit aquastat with a 100°F–240°F temperature range and a 1/2-inch NPT connection. Also verify the mounting dimensions, capillary arrangement, and equipment model against the manufacturer's documentation.

How should I maintain the Resideo L4006A1009 Aquastat Controller?

Have a qualified technician periodically inspect the sensing installation, electrical connections, and switching response. Check that the controller responds consistently to changes in liquid temperature and the selected control settings.