The BASO Gas Products K16BT-36H Husky Heavy Duty Thermocouple is a sturdy temperature measuring equipment used on gas appliances and has a length of 36 inches. It works by producing an open circuit voltage of 25 to 35 mV to the temperature fluctuations and with a maximum hot junction temperature of 1500°F. This thermocouple is suitable for HVAC equipment including commercial ovens and heaters to ensure its proper functioning in harsh conditions. Advantages are better safety due to accurate temperature control, increased heat resistance, and suitability for use with different types of gas appliances.
https://www.partshnc.com/media/catalog/product/k/1/k16bt-36h.jpg

Specifications

  • Type: Husky Heavy Duty Thermocouple W/Nut
  • Length: 36"
  • Application: Gas appliances
Manufacturer Name: BASO Gas Products
Product Number: K16BT-36H
OEM Part Number: K16BT-36H
Product Description: 36" Husky Heavy Duty Thermocouple With Nut
Weight:0.5lbs/226.8g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:BASO Gas Products K16BT-36H 36" Husky Heavy Duty Thermocouple W/Nut
Your Rating
Customer Questions
What maintenance is required for the BASO Gas Products K16BT-36H Thermocouple?

Regularly inspect the thermocouple for corrosion, dirt, or bent components. Ensure connections are tight and free from oxidation. Clean gently if necessary and check proper alignment. Follow safety procedures when working with gas appliances.

What are common issues with the BASO Gas Products K16BT-36H Thermocouple?

  • Failure to detect or maintain flame.
  • Intermittent or weak signal.
  • Corrosion or buildup on the sensor tip.
  • Loose or damaged connection nuts.

Installation Steps

Step 1: Turn off gas supply and allow system to cool before starting.

Step 2: Remove old thermocouple from pilot assembly and control valve connection.

Step 3: Position new thermocouple near pilot flame bracket and align nut.

Step 4: Hand-tighten then secure nut to gas valve, ensuring firm contact.

Step 5: Restore gas, test pilot ignition, check for stable flame and leaks.