Facebook Pixel

Trane INS1719 Burner Insulation 8.76/19.2"

Special Price $197.94 Regular Price $227.64
In stock
SKU
INS1719
The Trane INS1719 is a 8.76 x 19.5” burner insulation that is specially made to enhance the performance of Trane HVAC equipment, especially furnaces. It serves the purpose of the thermal protector, it surrounds the burner and confines heat produced at the time of combustion within the combustion chamber. This trapped heat leads to optimisation of fuel and reduction to heat loss that radiates in all directions. The Trane INS1719 protects other parts from heat therefore, helps them to last longer. Constructed from high quality materials, the Trane INS1719 can handle high heat, usually up to 1600 degrees Fahrenheit, thus providing long service and proper functioning of your Trane HVAC system.
Manufacturer:
https://www.partshnc.com/media/catalog/product/i/n/ins1719.jpg

Specifications

  • Length: 19.5"
  • Weight: 1.04lbs
  • Inside Diameter: 8.76"
  • Temperature Range: 1600 Deg F
Manufacturer Name: Trane
Product Number: INS1719
OEM Part Number: INS1719
Product Description: 8.76X19.2 Burner Insulation
Weight:1.04lbs/471.74g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Trane INS1719 Burner Insulation 8.76/19.2"
Your Rating
Customer Questions
What maintenance is required for the Trane INS1719 Burner Insulation?

Regularly inspect the Burner Insulation for cracks or heat damage. Clean surrounding burner area to prevent debris buildup affecting insulation performance. Ensure proper fit during servicing to maintain thermal efficiency and safe operation.

What are common issues with the Trane INS1719 Burner Insulation?

  • Insulation degradation from high heat exposure in burner assemblies.
  • Cracking or brittleness over time.
  • Improper fit causing heat loss and reduced efficiency.
  • Contamination from soot or debris affecting efficiency and airflow.

Installation Steps

Step 1: Turn off power and gas supply and allow unit to cool completely for safety.

Step 2: Remove furnace access panel carefully.

Step 3: Inspect and remove old or damaged insulation.

Step 4: Clean mounting area and remove debris.

Step 5: Position new burner insulation in place and align correctly.

Step 6: Secure firmly and ensure proper fit, check stability.

Step 7: Reassemble panel and test system operation and restore power.