Facebook Pixel

Carrier 326058-755 Inducer Assembly

Special Price $709.32 Regular Price $887.95
In stock
SKU
326058-755
The Carrier 326058-755 is a 2-stage inducer assembly, which is a part of the gas furnaces. It is a cooling fan that takes out safely, combustion gases and simultaneously intakes fresh air for proper working. This facilitates correct airing and averts the build up of dangerous gases in the home. The 2-stage functionality is designed to provide the better performance at low and high heating requirements. This inducer assembly is CSA listed and safe, and complies with the required standards. Advantages include removal of combustion exhaust, increased efficiency of furnace and safety in that adequate air supply to the burner is provided.
Manufacturer:
https://www.partshnc.com/media/catalog/product/p/a/partshnc_carrier_inducer_assembly_326058755.jpeg

Specifications

  • Length: 12.5 "
  • Width: 13.8 "
  • Height: 8 "
  • CSA Listing: Yes
  • UOM: EA
  • Weight: 8.89 Lbs
Manufacturer Name: Carrier
Product Number: 326058-755
OEM Part Number: 326058-755
Product Description: Inducer Assembly
Weight:8.59lbs/3896.36g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Carrier 326058-755 Inducer Assembly
Your Rating
Customer Questions
What maintenance is required for the Carrier 326058-755 Inducer Assembly?

Service attention should focus on keeping the inducer housing clear so combustion gases can exit without restriction. Any buildup around the wheel or vent path should be removed during routine inspections to avoid airflow degradation. It’s also essential to confirm stable mounting and check that electrical connections are not heat-stressed or loosening over time.

What are common issues with the Carrier 326058-755 Inducer Assembly?

  • Motor struggles to reach full speed at startup.
  • Abnormal rattling from worn bearings or loose wheel.
  • Pressure switch failures caused by weak draft flow.
  • Electrical burnout from prolonged overheating cycles.
  • Blocked vent path reducing combustion exhaust efficiency.
  • Intermittent shutdowns during ignition sequence.

Installation Steps

Step 1: Turn off electrical power and gas supply, and ensure the system is fully cooled before starting.

Step 2: Remove the access panel and label all wiring and tubing connections for correct reassembly.

Step 3: Disconnect electrical plugs, pressure switch tubing, and mounting fasteners from the existing inducer assembly.

Step 4: Carefully remove the old inducer assembly from the housing area.

Step 5: Position the new inducer assembly, align it properly, and secure all mounting points.

Step 6: Reconnect wiring and tubing, restore power and gas, then verify proper draft and ignition sequence operation.