Facebook Pixel

Carrier 50HE400792 Induced Draft Assembly

Special Price $1,442.90 Regular Price $1,601.62
In stock
SKU
50HE400792
The Carrier 50HE400792 is an induced draft assembly, which is a vital part of many Carrier furnace models. It has a significant function in safe and effective through the elimination of the combustion gases generated during the burning of fuel. The assembly contains a motor with a fan blade that rotates at high speed to generate a negative pressure chamber in the furnace. This negative pressure, it sucking exhaust gases in the combustion chamber and expels them through a flue pipe outside thus providing for adequate flow and avoiding any build-up of toxic gases inside. The specific Carrier-induced draft assembly is intended for the 460V single-phase electrical power systems.
Manufacturer:
https://www.partshnc.com/media/catalog/product/5/0/50he400792.jpg

Specifications

  • Length: 12.5 "
  • Width: 9.375 "
  • Height: 9.25 "
  • Weight: 11.25lbs
  • Voltage: 460V
  • Bearing Type: Ball
  • Frequency: 50 Hz
  • Amperage: 0.3
  • Horsepower: 1/16 HP
  • Phase: 1
  • RPM: 3450
  • Rotation: Counter Clockwise
Manufacturer Name: Carrier
Product Number: 50HE400792
OEM Part Number: 50HE400792
Product Description: Induced Draft Assembly
Weight:11.25lbs/5102.91g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Carrier 50HE400792 Induced Draft Assembly
Your Rating
Customer Questions
What maintenance is required for the Carrier 50HE400792 Induced Draft Assembly?

Disconnect power before inspecting the assembly and check the fan wheel spins freely without rubbing or resistance. Remove any dust, soot, or debris buildup that can disrupt airflow balance. Check wiring integrity and ensure all mounting points remain tight to prevent vibration-related damage during operation cycles.

What are common issues with the Carrier 50HE400792 Induced Draft Assembly?

  • Weak or inconsistent draft pressure during operation.
  • Motor failure preventing startup of the inducer.
  • Excess vibration caused by imbalanced fan wheel.
  • Electrical shorting or intermittent power supply issues.
  • Airflow restriction due to internal contamination buildup.

Installation Steps

Step 1: Turn off electrical power and gas supply confirm unit is fully isolated.

Step 2: Remove access panel and disconnect existing induced draft assembly wiring and mounting screws.

Step 3: Position new induced draft assembly and secure with mounting points ensure alignment.

Step 4: Reconnect wiring per diagram and verify blower operation before restoring power.

Step 5: Replace panel and restore power test for proper draft and combustion safety.