International Comfort Products ZP54K5E-TFD-830 54,000 BTU Scroll Compressor R410A/R410B 380/420/460V 3-Phase 50/60Hz

Special Price $1,270.92 Regular Price $1,410.72
Out of stock
SKU
ZP54K5E-TFD-830
The International Comfort Products ZP54K5E-TFD-830 Scroll Compressor R410A/R410B 380-420/460V/3PH 50/60Hz 54000 BTU is a refrigeration component used to compress refrigerant vapor within cooling equipment of the system. It is installed beneath the coil section of air handling units, where it collects liquid formed during cooling cycles. Working within HVAC systems, it directs moisture away from internal areas, supports proper drainage control, and coordinates with connected components to maintain proper equipment operation during cooling processes and service activities of system operations.
https://www.partshnc.com/media/catalog/product/z/p/zp54k5e-tfd-830.jpg

Air-conditioning systems use refrigeration cycles to transfer heat and maintain the cooling conditions required for operation. The International Comfort Products ZP54K5E-TFD-830 is a Scroll Compressor that performs the compression stage within this cycle. It increases refrigerant vapor pressure before the refrigerant continues through the refrigeration circuit. This pressure change supports refrigerant movement through the cooling process and allows the compressor to perform its role within the system.

SCROLL COMPRESSION OPERATION:
A scroll compressor uses stationary and orbiting spiral elements to compress refrigerant vapor. As the orbiting element moves, enclosed pockets carry the vapor inward while progressively reducing their volume. This action increases refrigerant pressure before the compressed vapor leaves the compressor. The ZP54K5E-TFD-830 operates with a 380–420/460V, three-phase electrical configuration at 50–60Hz.

REFRIGERANT AND REFRIGERATION-CYCLE ROLE:
The ZP54K5E-TFD-830 has a stated capacity of 54,000 BTU. After compression, refrigerant vapor moves toward the condenser, where heat is released before the refrigerant continues through the remaining stages of the refrigeration cycle. The compressor is listed for R410A and R410B refrigerants, and the refrigerant used must correspond with the compressor and applicable system requirements.

REPLACEMENT GUIDELINES:
Replacement may be appropriate when a confirmed compressor fault prevents the air-conditioning system from maintaining the required cooling operation. It may also be necessary when the existing compressor is identified for replacement through the applicable equipment service information. Before ordering, compare the existing compressor's part number and applicable system requirements with the replacement requirements.

COMMON FAILURE SYMPTOMS:

  • The compressor does not start during an operating cycle.
  • The air-conditioning system provides insufficient cooling.
  • The compressor repeatedly shuts down during operation.
  • Abnormal noise or vibration occurs while the compressor is running.
  • A protective device trips during compressor operation.

EQUIPMENT COMPATIBILITY:
The International Comfort Products ZP54K5E-TFD-830 Scroll Compressor is associated with the ZP51LXE-TFD-800 model reference provided for the application. Before installation, verify the equipment model and compare the required compressor capacity, electrical configuration, refrigerant requirements, and physical connection requirements with the original equipment documentation.

TECHNICAL SPECIFICATIONS:
Part Identification:
Brand: International Comfort Products
Part Number: ZP54K5E-TFD-830
Product Type: Scroll Compressor
Capacity Performance:
Capacity: 54,000 BTU
Electrical Specifications:
Voltage: 380/420/460V
Phase: 3-Phase
Frequency: 50/60Hz
Refrigeration Specifications:
Listed Refrigerants: R410A/R410B

Write Your Own Review
You're reviewing:International Comfort Products ZP54K5E-TFD-830 54,000 BTU Scroll Compressor R410A/R410B 380/420/460V 3-Phase 50/60Hz
Your Rating
Customer Questions
What maintenance is required for the ICP ZP54K5E-TFD-830 Compressor?

Regularly check oil levels, inspect for leaks, and clean air intake filters. Ensure refrigerant pressures are within specifications. Proper maintenance prevents inefficiency and overheating, and always turn off power before servicing for safety.

What are common issues with the ICP ZP54K5E-TFD-830 Compressor?

  • Compressor making vibrating sounds.
  • Lower than expected cooling performance.
  • Frequent system trips or thermal shutdowns.
  • Irregular oil circulation or pressure drops.

Can another 54,000 BTU scroll compressor replace the ZP54K5E-TFD-830?

Not automatically. The replacement must meet the equipment manufacturer's requirements for electrical configuration, refrigerant, operating conditions, capacity, and physical connections.

How can I confirm whether the ZP54K5E-TFD-830 is the correct replacement for my equipment?

Check the complete equipment model and serial number, the original compressor part number, and the manufacturer's parts documentation. The associated model reference alone is not sufficient confirmation.

Can the R410A and R410B refrigerant listings be treated as interchangeable?

No. Confirm the refrigerant approved for the specific compressor and equipment application. Do not substitute refrigerants based only on the listing without manufacturer approval.

What information should I provide when ordering this compressor?

Provide the complete ZP54K5E-TFD-830 part number, equipment model and serial number, and the specifications shown on the existing compressor label. This helps verify the required replacement.

Why might an air-conditioning system trip electrical protection after compressor startup?

Possible causes include supply-voltage problems, wiring faults, starting or control issues, or an internal compressor fault. A qualified technician should identify the cause before replacement.

Installation Steps

Step 1: Turn off power to the HVAC system and unplug the unit.

Step 2: Drain any refrigerant safely following local regulations.

Step 3: Remove the old compressor, noting wiring and line connections.

Step 4: Install the new compressor, reconnecting lines and electrical wiring.

Step 5: Evacuate the system, check for leaks, and recharge with refrigerant.

Step 6: Restore power, test operation, and ensure proper function.