The Carrier HT01BC701 is a transformer that is particularly made for HVAC equipment. It steps down electrical current from one voltage level to another voltage level. In this case, the takes 460 volts primary and transforms it into 230 volts secondary. This voltage adjustment is essentialin powering several parts in the HVAC systems that use lower voltages. Alright, let’s look at how a transformer functions in more detail it uses the principles of electromagnetism. It has a core made of metal along with coils of wire. AC when passes through the primary coil produces a magnetic field.
Manufacturer:
https://www.partshnc.com/media/catalog/product/h/t/ht01bc701_carrier_partshnc.png

Specifications

  • Voltage: 460-230V
  • Weight: 13.83lbs
  • Length: 5.5 "
  • Width: 4.25 "
  • Height: 3.25 "
Manufacturer Name: Carrier
Product Number: HT01BC701
OEM Part Number: HT01BC701
Product Description: 460Vpri 230Vsec 1564Va Xfrmr
Weight:13.83lbs/6273.18g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Carrier HT01BC701 Transformer 460V 230V SEC/1564VA PRI
Your Rating
Customer Questions
What maintenance is required for the Carrier HT01BC701 Transformer?

Regularly inspect the transformer for dust, moisture, or signs of overheating. Ensure all electrical connections are tight and insulation is intact. Keep the area well-ventilated and free of debris. Proper maintenance prevents voltage irregularities and ensures reliable operation.

What are common issues with the Carrier HT01BC701 Transformer?

  • Overheating during operation.
  • Loose or corroded electrical connections.
  • Insulation breakdown causing shorts.
  • Noise or humming from internal winding issues.

Installation Steps

Step 1: Turn off power to the system to prevent electrical shock.

Step 2: Locate the existing transformer and disconnect all primary and secondary wiring.

Step 3: Remove the old transformer from its mounting position.

Step 4: Mount the new transformer securely in the same location.

Step 5: Reconnect all wires to the correct primary and secondary terminals.