Honeywell V48A2185 1 1/2" Gas Valve 120V 1/2 PSI Normally Closed

Special Price $444.12 Regular Price $492.97
In stock
SKU
V48A2185
The Honeywell V48A2185 1 1/2" Gas Valve for use on a variety of heating and cooling systems. This 120-volt gas valve is normally closed and operates at 1/2 PSI, restricting gas flow until a signal is given to open. It controls the movement of gas to the burner in response to a thermostat, or other control system signal. On signal from the thermostat, the gas valve opens and allows gas through to the burner. The thermostat tells the gas valve to stay closed until the temperature goes down, but when the gas valve is closed, the gas flow is cut off to the burner.
https://www.partshnc.com/media/catalog/product/v/4/v48a2185.jpg

Specifications

  • Type: Gas Valve
  • Size: 1 1/2"
  • Voltage: 120V
  • Pressure: 1/2 PSI
  • Valve Type: Normally Closed (NC)
Manufacturer Name: Honeywell
Product Number: V48A2185
OEM Part Number: V48A2185
Product Description: 1 1/2"120V Gas Valve 1/2# N/C
Weight:4.26lbs/1932.3g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Honeywell V48A2185 1 1/2" Gas Valve 120V 1/2 PSI Normally Closed
Your Rating
Customer Questions
How to install an expansion valve for refrigeration?

Thermostatic expansion valves are an integral part of your refrigeration unit. They are responsible for ensuring the right dosage of refrigerant is entering the cooling coil to ensure maximum efficiency in the air conditioning of the system.    These special expansion valves come with a temperature sensor that is mounted at the end of the evaporator coil. They incorporate signals from this sensor to maintain the required temperature of the HVAC system. The thermostatic expansion valve works like a precision device that can regulate the measurements of the liquid refrigerant that flows into the evaporator of your system. This regulation in the flow of the refrigerant is essential to prevent the reverse flow of the refrigerant into the compressor of your system.    Through this mechanism, the thermostatic expansion valve successfully separates the high and low pressure sides of the refrigeration/air conditioning system. The liquid refrigerant enters the expansion ...

Please, mind that only logged in users can submit questions