Resideo GS250 2-1/2" Dial Thermometer W/Well

Special Price $35.70 Regular Price $46.41
In stock
SKU
GS250
The Resideo GS250 Thermometer with Well used in measuring the temperature to check the efficiency of the HVAC systems. It measures fluid temperature with the use of a thermal well integrated into the part. It has a sweat connection for easy and firm connection, and it has a 2-1/2” dial for simple visibility of the readings. It is widely used in boilers, water heaters and hydronic systems to increase system availability by allowing for easy troubleshooting. It is also built to last which makes it suitable for long term. This thermostat enhances the system's efficiency, reduces the time that the system is off and increases energy utilization in heating and cooling processes.
Manufacturer:
https://www.partshnc.com/media/catalog/product/g/s/gs250.jpg

Specifications

  • Type: Thermometer
  • Dial Size: 2-1/2"
  • Connection Type: Sweat

Product Overview:
Measures and displays temperature in heating and hydronic system applications using a dial thermometer with a well. The Resideo GS250 Dial Thermometer is an OEM temperature-monitoring component featuring a 2-1/2-inch dial and a temperature range of 32°F–250°F. Its included well supports the thermometer's installation in applications requiring the specified temperature range and mounting configuration.

Temperature Measurement:
Measures the temperature of fluid within a hydronic heating system and presents the reading through the dial display. The thermometer uses its sensing element to respond to the temperature of the monitored fluid, while the 2-1/2-inch dial provides a visible indication of the measured condition. The included thermowell forms the interface between the sensing assembly and the hydronic system, allowing the thermometer to function as a dedicated temperature-measuring component.

Hydronic Temperature Monitoring:
Within a hydronic heating system, the thermometer provides a localized indication of circulating water temperature for observation of the system's thermal condition. The dial allows the measured temperature to be viewed directly at the monitoring point, while the thermowell maintains the defined sensing arrangement between the thermometer and the fluid circuit. This makes the assembly suitable for hydronic applications where direct temperature indication is required.

Replacement Guidelines:
Replacement may be considered when the existing thermometer shows signs of damage or no longer provides the required temperature indication. Before selecting a replacement, verify the GS250 part number, dial configuration, thermowell arrangement, and applicable hydronic system requirements to confirm that the replacement thermometer is suitable for the intended application.

Common Failure Symptoms:

  • No usable temperature indication on the dial.
  • Damaged or unreadable dial markings.
  • Temperature indication that does not provide a usable reading.
  • Physical damage to the thermometer assembly.
  • Physical damage to the included well.

Equipment Compatibility:
The Resideo GS250 is categorized for hydronic systems and is intended for equipment applications where this specific thermometer assembly is specified. Compatibility should be based on the equipment documentation and the required thermometer configuration rather than on general use with unrelated HVAC equipment.

Technical Specifications:
Brand: Resideo
Part Number: GS250
Component Type: Dial thermometer with well
Dial Size: 2-1/2"
Included Component: Well
Temperature: 32°F- 250°F

Write Your Own Review
You're reviewing:Resideo GS250 2-1/2" Dial Thermometer W/Well
Your Rating
Customer Questions
What is the Resideo GS250 hydronic thermometer used for?

The GS250 provides a visible dial reading of temperature in a hydronic heating system and is supplied with a thermowell.

What should I check before selecting the GS250 thermometer?

Verify the required temperature range, connection arrangement, installation requirements, and thermowell configuration against your system specifications.

Why might a hydronic thermometer display an unexpected temperature reading?

An incorrect reading may result from a faulty thermometer, an installation issue, or a difference between the measured location and the system's actual operating condition.

When should a hydronic thermometer be replaced?

Consider replacement if the dial is damaged, the reading is consistently unreliable, or the thermometer fails to provide a usable temperature indication after inspection.

What maintenance should be performed on a hydronic thermometer assembly?

During scheduled heating-system servicing, check the dial, visible connections, and thermowell area for damage or signs of leakage.