The Nidec-Embraco FF8.5HBK1 Compressor is a refrigeration compressor designed for systems requiring R134A refrigerant and a 115-volt single-phase power supply. It compresses refrigerant within the cooling circuit, moving it through the refrigeration cycle so heat can be transferred from the refrigerated space. In HVAC systems and related refrigeration equipment, the compressor operates with components such as the condenser, expansion equipment, and evaporator as components of the complete circuit. Its 1/4 horsepower rating identifies the motor capacity, while the R134A specification identifies the refrigerant used during operation.

https://www.partshnc.com/media/catalog/product/f/f/ff8.5hbk1.png

Specifications

  • Type: Compressor
  • Horsepower: 1/4 HP
  • Refrigerant: R134A
  • Voltage: 115V
  • Phase: 1 PH
Manufacturer Name: Nidec-Embraco
Product Number: FF8.5HBK1
OEM Part Number: FF8.5HBK1
Product Description: 115V1ph R134a 1/4Hp Compressor
Weight:23.08lbs/10468.9g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Nidec-Embraco FF8.5HBK1 1/4HP Compressor R134A 115V/1PH
Your Rating
Customer Questions
What maintenance is required for the Nidec-Embraco FF8.5HBK1 Compressor?

Regularly check for refrigerant leaks and ensure proper electrical connections. Clean the condenser and evaporator coils to maintain efficiency. Inspect mounting and vibration isolation to prevent noise and mechanical stress. Always follow safety protocols when handling refrigerants.

What are common issues with the Nidec-Embraco FF8.5HBK1 Compressor?

  • Overheating or tripping of thermal protection.
  • Refrigerant leaks or low pressure.
  • Unusual noise or vibration.
  • Failure to start or intermittent operation.

Installation Steps

Step 1: Disconnect power and recover refrigerant safely using proper equipment.

Step 2: Remove old compressor and clean suction and discharge lines thoroughly.

Step 3: Mount new compressor securely with vibration pads and correct orientation.

Step 4: Braze suction and discharge joints, ensuring correct oil charge and leak-free seals.

Step 5: Vacuum system, perform leak test, recharge refrigerant, then restore power carefully.