Facebook Pixel

Carrier EA36YP144 Thermal Expansion Valve (TXV) Valve

Special Price $140.62 Regular Price $161.71
In stock
SKU
EA36YP144
The Carrier EA36YP144 is a Thermostatic Expansion Valve, seen in many HVAC systems including air conditioners and heat pumps. Its function is essential to control of refrigerant flow throughout the system. The bi metallic coil used on this TXV expands and contracts with temperature change. The opening of a valve to let the just right amount of refrigerant into the evaporator coil is controlled by this expansion and contraction. This valve maintains the desired temperature in the evaporator coil optimizing system performance and efficiency.
Manufacturer:
https://www.partshnc.com/media/catalog/product/e/a/ea36yp144.jpg

Specifications

  • Size: 3.9 x 4.7 x 5.2 "
  • Composition: Bi-Metal
  • Metering Device: TXV/TEV-Thermostatic Expansion Valve
  • Prop 65: Yes
  • Refrigerant: Various
  • Weight: 0.76lb

PRODUCT OVERVIEW:
Provides an OEM refrigerant metering component for compatible Carrier heating, air conditioning, and refrigeration equipment. The Carrier EA36YP144 Thermal Expansion Valve (TXV) regulates liquid refrigerant entering the evaporator coil according to changing thermal conditions. By modulating refrigerant mass flow, the valve supports controlled evaporator superheat and helps prevent unevaporated liquid refrigerant from returning through the suction line. This metering action also supports active heat absorption across the evaporator assembly during system operation.

PRESSURE DROP ACROSS THE VALVE:
At the metering point, liquid refrigerant encounters a controlled restriction that produces a pressure differential between the upstream and downstream sides. This pressure change establishes the transition from the higher-pressure liquid circuit toward the lower-pressure evaporator condition. The resulting pressure relationship prepares the refrigerant for expansion and movement through the evaporator.

INTERNAL FLOW PATH CONTROL:
Within the valve assembly, the internal passage directs refrigerant between the connected sections of the refrigeration circuit. Movement through this passage is governed by the internal control arrangement, while the check-valve mechanism supports directional refrigerant management where required. This configuration allows the assembly to manage refrigerant movement as operating conditions change.

REPLACEMENT GUIDELINES:
Replacement of Carrier EA36YP144 may be appropriate when the existing thermal expansion valve develops refrigerant leakage, restricted flow, inconsistent metering, or an improper response to changing system conditions. Replacement may also be necessary when physical damage affects the valve assembly or internal flow-control components. Replacing the affected valve should restore the intended refrigerant metering relationship within the applicable refrigeration circuit.

Common Failure Symptoms:

  • Heavy frost or ice buildup at the evaporator coil inlet
  • Abnormally low suction pressure accompanied by elevated superheat
  • Inability of the cooling equipment to maintain target temperature output
  • Starved evaporator coil resulting from restricted fluid metering
  • Intermittent system shutdowns triggered by low-pressure safety controls

EQUIPMENT COMPATIBILITY:
The Carrier EA36YP144 Thermal Expansion Valve (TXV) is an OEM component designed for use in compatible Carrier HVAC systems. Verify the equipment manufacturer (Carrier) and part number (EA36YP144) against the applicable system documentation before selecting the replacement assembly.

Technical Specifications:
Product identification:
Manufacturer: Carrier
Part Number: EA36YP144
Component Type: Thermal Expansion Valve (TXV)

Write Your Own Review
You're reviewing:Carrier EA36YP144 Thermal Expansion Valve (TXV) Valve
Your Rating
Customer Questions
What maintenance is required for the Carrier EA36YP144 Thermal Expansion Valve?

Regularly inspect the valve for leaks, corrosion, or debris buildup. Ensure proper refrigerant flow and check that connections are secure. Clean surrounding components carefully and follow safety precautions when handling pressurized systems.

What are common issues with the Carrier EA36YP144 Thermal Expansion Valve?

  • Refrigerant leaks or dripping.
  • Inconsistent cooling or temperature fluctuations.
  • Valve sticking or failing to modulate flow.
  • Noise or hissing during operation.

Why is a TXV used instead of a fixed refrigerant restriction?

A TXV can adjust refrigerant admission according to changing system conditions, while a fixed restriction provides a predetermined flow path.

What role does a check valve play in a thermal expansion valve assembly?

A check valve helps manage refrigerant movement when the refrigeration circuit requires controlled flow in different directions.

What should be considered when handling a TXV during service?

The valve and its associated control components should be handled according to the applicable equipment service procedures to avoid damage during service.

Why should TXV service work be documented?

Recording the component condition and service work provides a reference for future troubleshooting and equipment maintenance.

Installation Steps

Step1: Turn off power and ensure the system is depressurized.

Step2: Remove the existing valve carefully.

Step3: Clean the pipe ends or connection points.

Step4: Install the new thermal expansion valve in the correct flow orientation.

Step5: Secure fittings and tighten connections properly.

Step6: Restore system pressure and power, then check for leaks and proper operation.