The Regal Rexnord - Fasco D114 1/12HP Single-Speed Fan Coil Motor that used in air conditioning systems. The fan coil unit operates with this motor to a distribute heated or cooled air through the system. The motor operates at 1550 RPM to provide steady airflow. The motor operates with two power supply options which allow it to work with 115V and 230V electrical systems. The motor design features noise reduction technology to reduce disturbances. The motor delivers dependable operation together with high energy efficiency and longevity which creates an environment that feels comfortable indoors. The HVAC system component primarily uses this part in fan coil units to regulate temperatures effectively.
1/12Hp 115/230V 1550Rpm Motor Regal Rexnord - Fasco D114
The Regal Rexnord - Fasco D114 is a 1/12 horsepower, single-phase, 60 Hz electric motor commonly used in various HVAC applications like fan coils and air conditioners. This compact and efficient motor packs a punch, making it a reliable choice for many residential and commercial use cases. are 1/12Hp 115/230V 1550Rpm Motor D114 single-phase AC motor. It's a versatile motor used in various applications, with several potential functions depending on the specific equipment it's used in. Here's a breakdown of the known information and possible applications:
Key Features:
Horsepower: 1/12 HP – ideal for tasks requiring moderate power, like driving fan blades in HVAC systems.
Phase: Single-phase – compatible with most standard household electrical systems.
Frequency: 60 Hz – suitable for use in North America and other regions with 60 Hz power grids.
Voltage: 115/230 V (dual voltage) – can operate on both standard and higher voltage power supplies, offering flexibility in installation.
Speed: 1550 RPM – delivers a consistent and efficient airflow for optimal cooling or heating performance.
Diameter: Its small size of 4.4 inches makes it perfect for confined places found in HVAC equipment.
Frame: TEAO – enclosed design protects internal components from dust, moisture, and debris, ensuring long-lasting operation.
Type: Fan coil and air conditioner motor – specifically designed for the demands of HVAC applications.
Features: Single speed, TEAO enclosure, ball bearings – provides smooth and quiet operation with minimal maintenance needs.
Applications:
The Regal Rexnord - Fasco D114 is a versatile motor suitable for various HVAC applications, including:
Fan coils: These units circulate chilled or heated water within buildings, and the D114 motor drives the fan that blows air across the coil for temperature control.
Air conditioners: This motor can power the fan that blows cool air across the evaporator coil in an air conditioning unit.
Blowers: In ventilation systems, the D114 motor can drive blowers that circulate air throughout a building.
Other HVAC equipment: This motor's adaptability makes it a suitable choice for various HVAC equipment requiring a reliable and efficient power source.
Benefits:
Choosing the Regal Rexnord - Fasco D114 motor offers several advantages:
Compact and lightweight: Easy to install and maneuver in tight spaces.
Dual voltage compatibility: Provides flexibility for various power supply configurations.
Durable and reliable: Built with high-quality materials for long-lasting performance.
Quiet operation: Ball bearings reduce vibration and noise.
Readily available: Widely stocked by appliance parts retailers and distributors.
Signs of a Faulty D114 1/12Hp 115/230V 1550RpmMotor Regal Rexnord - Fasco:
The Regal Rexnord - Fasco D114 motor is a workhorse in many HVAC systems. But like any mechanical equipment, it's prone to wear and tear, and knowing the signs of a faulty motor can save you from headaches and costly repairs down the line. These are some indicators to watch out for.
1. Overheating:
Feel the motor: If the motor feels hot to the touch, even after a short period of operation, it's a sign of excessive internal friction or strain. A clogged rotor, damaged bearings, or insufficient airflow might all be the cause of this.
2. Unusual Noises:
Listen closely: Grinding, screeching, or humming noises that weren't present before are indicators of internal issues. These noises could be caused by worn bearings, a damaged rotor, or misaligned components.
3. Reduced Performance:
Observe the airflow: If the fan driven by the motor isn't spinning as fast as usual or struggles to maintain its speed under load, it could be due to worn brushes, a weak capacitor, or a faulty winding.
4. Burning Smell:
Sniff for trouble: If you detect an electrical burning smell emanating from the motor, it's a serious warning sign of overheating and potential fire hazard. As soon as possible, turn off the electricity and get expert assistance.
5. Visible Damage
Inspect the motor: Look for cracks or damage to the housing, loose or broken wires, or any visible signs of physical impact. These could compromise the motor's integrity and safety.
Bonus Tip:
Monitor your energy bills: A sudden spike in electricity consumption could indicate the 1/12Hp 115/230V 1550Rpm Motor D114 is working harder than usual due to inefficiency or internal problems.
Choose the best HVAC equipment parts and supplies from PartsHnC!