CSP-4702
KMC Controls CSP-4702 Analog Differential Pressure VAV Controller Actuator is a versatile and efficient part that is used for the precise airflow control in HVAC systems. Controller actuator operates at 16 VDC and adjusts airflow on variable air volume VAV terminal units by regulating airflow. In commercial developments, it is normally used to indoor air quality and also the energy effectiveness of the facility. The CSP 4702 I Provides accurate modulation, decreased energy consumption with optimal comfort. It is integrated to HVAC system to provide balanced airflow, decrease operation cost and enhance environmental control. This allows for VAV box applications while increasing the system reliability and performance in variable air volume applications.
Manufacturer:
https://www.partshnc.com/media/catalog/product/c/s/csp-4702.jpg

Specifications

  • Type: Controller Actuator
  • Input Voltage: 16 VDC
Manufacturer Name: KMC Controls
Product Number: CSP-4702
OEM Part Number: CSP-4702
Product Description: Dif Press Vav Cntrlr,16Vdc Out
Weight:1.11lbs/503.49g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:KMC Controls CSP-4702 Analog Differential Pressure VAV Controller Actuator 16 VDC
Your Rating
Customer Questions
What maintenance is required for the KMC Controls CSP-4702 VAV Controller/Actuator?

Inspect tubing connections and pressure ports regularly to ensure accurate differential pressure sensing. Keep the actuator housing clean and verify smooth damper movement. Check wiring, control signals, and mounting stability to maintain accurate airflow control and prevent operational drift.

What are common issues with the KMC Controls CSP-4702 VAV Controller/Actuator?

  • Inaccurate pressure readings due to sensor drift or clogged ports.
  • Actuator response delay or failure to modulate airflow correctly.
  • Wiring faults or intermittent power supply issues.
  • Air tubing leaks causing unstable VAV control action.

Installation Steps

Step 1: Turn off HVAC system power before installation to avoid electrical shock or equipment damage.

Step 2: Mount the controller securely to the VAV box using the provided hardware.

Step 3: Connect airflow tubing to the high- and low-pressure ports correctly.

Step 4: Wire the actuator and control terminals following the manufacturer’s wiring diagram.

Step 5: Set calibration and airflow parameters as required for the HVAC system.

Step 6: Restore power, test damper movement, and verify proper pressure response and control operation.