Facebook Pixel

Superior Radiant CE266 Control Board

Special Price $151.39 Regular Price $174.10
In stock
SKU
CE266

The Superior Radiant CE266 Control Board is a crucial component used in HVAC systems for controlling and regulating the operation of radiant heating equipment. This control board operates by first coordinating the functioning of different heating elements in response to input signals it receives from thermostats or other temperature sensors. In order to provide the best possible comfort levels in the allocated space, it processes these signals and transmits commands to turn on or off the radiant heating system. Radiant heating systems used in commercial, industrial, and residential buildings frequently use the CE266 Control Board. Its advantages, which improve occupant comfort and lower energy expenses, include accurate temperature control, energy economy, and dependable operation. To further assure endurance and durability, the control board's sturdy construction reduces the need for maintenance.

https://www.partshnc.com/media/catalog/product/c/e/ce266_superior-radiant_partshnc.jpg
Manufacturer Name: Superior Radiant
Product Number: CE266
OEM Part Number: CE266
Product Description: Control Board
Weight:0.76lbs/344.73g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Superior Radiant CE266 Control Board
Your Rating
Customer Questions
What maintenance is required for the Superior Radiant CE266 Control Board?

For the Control Board, inspect wiring connections regularly for looseness or corrosion and ensure the unit stays free of dust and moisture. Ensure proper control prevents failures and improves heating system reliability. Always disconnect power before servicing.

What are common issues with the Superior Radiant CE266 Control Board?

  • Intermittent control signal failure due to relay wear or loose wiring.
  • Overheating or thermal cutoff triggering under heavy load conditions.
  • Unresponsive board from power surges or damaged capacitors.
  • Display or indicator errors affecting system diagnostics.

Installation Steps

Step 1: Turn off power and verify the system is completely de-energized.

Step 2: Open the control compartment and label all wiring connections.

Step 3: Disconnect plugs and remove mounting screws from the old control board.

Step 4: Install the new board, securing it in the same mounting position.

Step 5: Reconnect all wiring harnesses firmly to their correct terminals.

Step 6: Restore power and test system startup, ignition sequence, and safety lockout operation.