Facebook Pixel

Superior Radiant CE139 Digital Thermostat PSD010B

Special Price $74.13 Regular Price $85.25
In stock
SKU
CE139
The Superior Radiant CE139 Digital Thermostat PSD010B is a highly accurate temperature control part that is intended for use with infrared radiant heaters. It works through the detection of the surrounding conditions and turning on the HVAC equipment to the desired comfort level set by the user. Designed for commercial and industrial applications, it is compatible with other Superior Radiant heaters. The thermostat optimizes the use of energy by reducing wastage, maintaining a steady heat, and cutting on operating expenses. It has an interface to work with and a stable performance to work on in the long run.
https://www.partshnc.com/media/catalog/product/c/e/ce139.jpg

Specifications

  • Type: Digital Thermostat
  • Model: PSD010B

Product Overview:
Maintains comfortable indoor conditions by providing direct temperature control for designated radiant systems. The Superior Radiant CE139 Digital Thermostat PSD010B is an OEM control designed for radiant heating equipment and other heat-only configurations. Its clear display and accessible adjustment buttons allow users to manage the desired indoor setting conveniently.

Manual Setpoint Adjustment:
Front-panel buttons allow users to increase or decrease the desired indoor setting as needed. This arrangement provides direct control without requiring programmed schedules or automatic setback periods.

Heat-Only Equipment Regulation:
When the indoor setting calls for heat, the control signals the connected equipment to begin its heating cycle. This arrangement supports designated radiant systems that require temperature-based on-and-off control.

Replacement Guidelines:
Replace the Superior Radiant CE139 when the display becomes unresponsive, temperature adjustments fail to register, or the connected equipment does not respond to the control demand. Replacement may also be necessary if the housing, battery contacts, or wiring connections become damaged. Have a qualified HVAC technician assess the existing control arrangement and handle testing and replacement.

Common Failure Symptoms:

  • Display becomes blank or difficult to read
  • Adjustment buttons fail to respond
  • Equipment does not activate when called
  • Selected temperature settings are not maintained
  • Battery contacts or wiring connections show deterioration

Equipment Compatibility:
The Superior Radiant CE139 Digital Thermostat PSD010B is an OEM control designed for designated heat-only systems, including suitable radiant heaters, fireplaces, stoves, and hydronic heating equipment. It supports specified low-voltage two-wire and millivolt heating arrangements. Confirm the existing wiring and heating system type before purchasing.

Technical Specifications:
Brand: Superior Radiant
Part Number: CE139
Model Number: PSD010B
Product Type: Digital Heat-Only Thermostat

Write Your Own Review
You're reviewing:Superior Radiant CE139 Digital Thermostat PSD010B
Your Rating
Customer Questions
What maintenance is required for the Superior Radiant CE139 Digital Thermostat?

Keep the thermostat clean by gently wiping dust from the faceplate and ensuring vents are unobstructed. Periodically check wiring connections for tightness and signs of wear. Verify temperature calibration for accuracy. Avoid moisture exposure to prevent electrical hazards.

What are common issues with the Superior Radiant CE139 Digital Thermostat?

  • Inaccurate temperature readings due to sensor drift or poor calibration.
  • Unresponsive controls from wiring faults or loose connections.
  • Short cycling of system caused by faulty relay or thermostat miscommunication.
  • Display malfunction or blank screen from internal electronics failure.

Can the Superior Radiant CE139 control cooling equipment?

No. It is designed for heat-only operation and does not provide cooling control.

What types of systems can use this thermostat?

It supports designated two-wire low-voltage and millivolt systems, including suitable radiant and hydronic configurations.

What should be checked before replacing the CE139?

Verify the thermostat model, 24V or millivolt system requirements, heating-stage configuration, and wiring connections before installing a replacement.

Does the PSD010B require a programmed temperature schedule?

No. Its non-programmable design allows users to adjust the desired setting directly through the front controls.

What maintenance helps keep the display and buttons responsive?

Check the battery condition periodically and gently clean the front control surface to prevent dirt buildup from interfering with button operation.

Installation Steps

Step 1: Turn off main breaker power to avoid electrical shock.

Step 2: Remove old thermostat and carefully label existing wires.

Step 3: Mount backplate to wall using level and mounting screws.

Step 4: Connect line, load, neutral, and sensor wires per wiring diagram carefully.

Step 5: Attach new thermostat and secure front cover firmly.

Step 6: Restore power, set configuration, and test heating operation thoroughly.

Step 7: Ensure no exposed wires before powering on.