Facebook Pixel

Superior Radiant CE003 Flame Sensor Probe PSE-SP1

Special Price $31.33 Regular Price $40.73
In stock
SKU
CE003

The Superior Radiant CE003 Probe, Sense Pse-Sp1 is a cutting-edge component that improves the efficiency and performance of HVAC systems. This revolutionary probe detects numerous environmental characteristics such as temperature, humidity, and pressure, enabling for accurate control and optimization of heating, ventilation, and air conditioning systems. The CE003 Probe, which is specifically designed for use with HVAC systems, provides precise monitoring and modification of conditions within a room, resulting in increased comfort and energy savings. Its innovative technology allows for seamless interaction with current systems, giving customers greater control and flexibility in regulating interior temperatures. This probe improves overall HVAC performance by providing trustworthy data and allowing for quick changes, making it a useful tool in both commercial and residential contexts.

Manufacturer:
https://www.partshnc.com/media/catalog/product/c/e/ce003.jpg
Detects the presence of a burner flame and provides a corresponding electrical sensing response within combustion in HVAC systems. The Superior Radiant CE003 Probe Sensor PSE-SP1 operates by placing its sensing element at the designated flame-monitoring position, where exposure to combustion heat produces the electrical condition used by the associated control circuit. During operation, the probe’s sensing element interacts with the flame condition and supplies the resulting signal to the connected control system for flame-status recognition. It is used in burner assemblies where continuous flame detection forms part of the operating control sequence.

Flame Detection:
At the burner sensing point the probe responds to the thermal presence created by an established flame. The sensing tip remains positioned within the designated combustion area so that the flame condition can be distinguished from the surrounding burner environment. This thermal interaction establishes the sensing condition required during the applicable stage of burner operation, providing a defined basis for recognizing the presence of combustion.

Sensor Electrode:
Along the conductive portion of the probe the electrode forms the internal electrical interface associated with the sensing element. Its conductive structure provides continuity between the sensing portion and the external connection point, allowing the probe assembly to maintain its intended electrical pathway. The electrode’s physical arrangement supports consistent electrical conduction within the sensor without repeating the flame-detection process.

Replacement Guidelines:
Replacement requires matching Superior Radiant CE003 Probe Sensor PSE-SP1 sensing characteristics, electrode arrangement, physical configuration, connection requirements, and combustion-equipment specifications. The replacement should also suit the existing burner assembly and associated flame-control circuit.

Common Failure Symptoms:

  • Temperature readings become inaccurate during operation.
  • Sensor response becomes delayed or inconsistent.
  • Control response does not match actual conditions.
  • Probe fails to detect temperature changes.
  • Equipment cycles irregularly from incorrect sensing.

Equipment Compatibility:
The Superior Radiant CE003 Probe Sensor PSE-SP1 is intended for Integrates with combustion equipment requiring the corresponding flame-sensing configuration. Verify the equipment model, probe arrangement, electrical connections, and manufacturer’s documentation before purchasing.

Technical Specifications:
Brand: Superior Radiant
Part Number: CE003
Product Type: Probe Sensor
Model: PSE-SP1

Write Your Own Review
You're reviewing:Superior Radiant CE003 Flame Sensor Probe PSE-SP1
Your Rating
Customer Questions
What maintenance is required for the Superior Radiant CE003 Flame Sensor Probe?

Regularly clean the flame sensor probe using a soft cloth or fine sandpaper to remove soot and debris, ensuring accurate detection. Inspect wiring for wear or corrosion. Perform checks before each heating season to prevent false shutdowns and ensure safe operation. Always disconnect power before maintenance.

What are common issues with the Superior Radiant CE003 Flame Sensor Probe?

  • Failure to detect flame, causing shutdowns.
  • Intermittent flame signal due to loose connections.
  • Corrosion or buildup on the probe tip.
  • Electrical faults affecting sensor performance.

How does the sensing tip interact with the combustion area?

The sensing tip extends into the designated flame zone, where exposure to combustion conditions establishes the required sensing state.

What purpose does the conductive electrode serve?

The conductive electrode provides the electrical path from the sensing element to the external connection, allowing the detected response to reach the control circuit.

When is the flame-sensing response used by the burner controls?

The control uses the sensing response as part of its burner sequence to determine whether the required flame condition is present.

What electrical principle supports flame sensing in this probe?

The probe detects the electrical response associated with flame exposure, creating a signal that the related control circuit can recognize.

How can I confirm the CE003 flame-sensing probe before purchasing?

Match the CE003 designation and flame-sensing probe identification with the existing component and applicable burner-control information.

Installation Steps

Step1: Turn off gas and power to the heater before starting.

Step2: Remove the access panel and disconnect the old flame sensor wiring.

Step3: Unscrew and remove the old sensor from its bracket.

Step4: Install the new probe in the same position and tighten securely.

Step5: Reconnect the wiring to the correct terminal.

Step6: Restore power and test ignition to confirm proper sensing.