Carrier 328154-701 Drain Trap

Special Price $27.75 Regular Price $36.07
In stock
SKU
328154-701
The Carrier 328154-701 Drain trap which is used for HVAC equipment, high-efficiency furnaces in particular. A small but necessary addition that helps avoid clogs and bad smells in the condensate drain of your furnace. This compact trap, which is approximately 2.1 inch long, 3.1 inch wide, and 0.9 inch in height. While in use, your furnace cools water vapor in the air and turns it into condensation. The condensate produced by the drain trap is to control the flow of the water out of the furnace so that it does not flow backwards into the system.
https://www.partshnc.com/media/catalog/product/0/0/0019344_0.jpg

Specifications

  • Type: Drain Trap
  • Weight: 0.27lbs
  • Length: 2.1 "
  • Width: 3.1 "
  • Height: 0.9 "
Manufacturer Name: Carrier
Product Number: 328154-701
OEM Part Number: 328154-701
Product Description: Drain Trap
Weight:0.27lbs/122.47g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Carrier 328154-701 Drain Trap
Your Rating
Customer Questions
How to install an expansion valve for refrigeration?

Thermostatic expansion valves are an integral part of your refrigeration unit. They are responsible for ensuring the right dosage of refrigerant is entering the cooling coil to ensure maximum efficiency in the air conditioning of the system.    These special expansion valves come with a temperature sensor that is mounted at the end of the evaporator coil. They incorporate signals from this sensor to maintain the required temperature of the HVAC system. The thermostatic expansion valve works like a precision device that can regulate the measurements of the liquid refrigerant that flows into the evaporator of your system. This regulation in the flow of the refrigerant is essential to prevent the reverse flow of the refrigerant into the compressor of your system.    Through this mechanism, the thermostatic expansion valve successfully separates the high and low pressure sides of the refrigeration/air conditioning system. The liquid refrigerant enters the expansion ...

What maintenance is required for the Carrier 328154-701 Drain Trap?

Periodically inspect for blockages caused by dirt, algae, or sludge buildup. Clean it using water flushing to ensure proper condensate flow. Check seals and joints for air leaks that could affect drainage performance and system efficiency.

What are common issues with the Carrier 328154-701 Drain Trap?

  • clogging due to dirt or algae buildup.
  • water backing up into the drain pan.
  • air leaks reducing proper condensate drainage.
  • cracked or damaged trap housing.
  • improper installation causing drainage failure.
  • foul odors from stagnant water accumulation.

Installation Steps

Step 1: Turn off system power and confirm no active flow in condensate line for safety.

Step 2: Remove access panel and disconnect existing drain trap carefully, noting pipe alignment.

Step 3: Clean drain outlet and surrounding connection area to ensure clear fit.

Step 4: Place new drain trap in correct orientation and secure to condensate line tightly.

Step 5: Check all joints for tightness, restore system power, and confirm smooth drainage without blockage.