Facebook Pixel

Resideo C7189U1005 Remote Indoor Temperature Sensor

Special Price $60.69 Regular Price $69.79
In stock
SKU
C7189U1005
The Resideo C7189U1005 Remote Indoor Temperature Sensor is designed to monitor the indoor temperature in HVAC systems efficiently. This sensor is perfect for wall mounting and has a slim build with a Premier White finish; it measures 1.5”W x 2.25”H so it can fit into any environment. It is capable of identifying temperatures up to 88°F, thus making it easy to regulate the climate. The sensor integrates well with compatible Resideo thermostats, optimising the HVAC through better temperature readings and comfort. This sensor is a key element for providing constant indoor conditions and saving energy due to its elegant design and high performance.
https://www.partshnc.com/media/catalog/product/c/7/c7189u1005_1.jpg

Specifications

  • Application: Indoor Temperature Sensing
  • Color:Premier White
  • Dimension :1.5"W x 2.25"H
  • Temperature: 88 °F
  • Mounting Type: Wall Mounted

Product Overview:
Monitors indoor temperature from a remote location and provides temperature feedback to the connected thermostat for heating and cooling control. The Resideo C7189U1005 Remote Indoor Temperature Sensor is an OEM temperature-sensing component featuring an NTC sensing element and designed for supported Resideo thermostat applications, including configurations that use wired temperature averaging.

Temperature Monitoring:
Measures room temperature through an NTC sensing element whose electrical resistance changes as temperature changes. The resistance decreases as temperature increases, allowing the connected thermostat to interpret the resistance change as a temperature value.

Control System Feedback:
Provides remote temperature information to the thermostat for use in temperature control. When multiple corresponding wired sensors are configured as a temperature-averaging network, the thermostat can combine their temperature readings according to its configured sensor arrangement.

Replacement Guidelines:
Replace the existing sensor with the Resideo C7189U1005 Remote Indoor Temperature Sensor when accurate indoor temperature monitoring is no longer maintained. Verify that the replacement matches the required sensing arrangement before replacing the existing component. Using the appropriate sensor helps support dependable temperature monitoring and consistent system operation.

Common Signs of Wear:

  • Visible damage to the sensor housing.
  • Damaged or deteriorated wiring.
  • Temperature readings that do not correspond with the actual room temperature.
  • Unstable or inconsistent temperature readings.
  • Loss of communication between the sensor and corresponding thermostat.

Equipment Compatibility:
The C7189U1005 is specified for corresponding Honeywell Home thermostats, including VisionPRO and VisionPRO IAQ thermostat applications identified by Resideo. It is intended for remote indoor temperature sensing and can participate in a temperature-averaging network where supported by the applicable thermostat configuration. The thermostat model and sensor arrangement should correspond with the requirements of the equipment before purchase.

Technical Specifications:
Brand: Resideo
Part Number: C7189U1005
Product Type: Remote Indoor Temperature Sensor
Sensing Element: NTC
Sensor Accuracy: ±1.5°F at 70°F
Maximum Sensor-to-Thermostat Distance: 250 ft

Write Your Own Review
You're reviewing:Resideo C7189U1005 Remote Indoor Temperature Sensor
Your Rating
Customer Questions
What does the NTC designation mean on the C7189U1005 sensor?

NTC identifies the sensing element used in the C7189U1005, where its electrical resistance decreases as the sensed temperature increases.

Why can a remote sensor be positioned away from the thermostat?

A remote sensor allows indoor temperature information to be obtained from a location separate from the thermostat, providing the control system with temperature data from that sensing location.

What happens when the C7189U1005 is part of a temperature-averaging network?

When multiple corresponding wired sensors are configured for averaging, the thermostat can combine their temperature readings according to its configured sensor arrangement.

What does the 200 ft specification represent for the C7189U1005?

The 200 ft specification identifies the maximum stated distance between the C7189U1005 sensor and the corresponding thermostat.

What is the purpose of using multiple C7189U1005 sensors in one temperature-averaging setup?

Multiple C7189U1005 sensors can provide temperature readings from different indoor locations when the corresponding thermostat supports a wired temperature-averaging configuration.