Facebook Pixel

Lochinvar & A.O. Smith 100112011 Burner Gasket

Special Price $24.53 Regular Price $31.89
In stock
SKU
100112011
The Lochinvar & A.O. Smith 100112011 Burner Gasket is a required sealing component to avoid gas or air escapes around the burner assemblies in HVAC systems. This works by ensuring there is a better seal between parts, which ensures the motor burns well and it works efficiently. The boiler, commercial, and residential furnace, as well as the water heater, are often fitted with it, which plays a major part in the system concept by controlling the flow of gas and enabling stable burning of the burner and the respective system conditions, which ensures safe and effective heating performance.
https://www.partshnc.com/media/catalog/product/1/0/100112011.jpg
Manufacturer Name: Lochinvar & A.O. Smith
Product Number: 100112011
OEM Part Number: 100112011
Product Description: Burner Gasket
Weight:0.02lbs/9.07g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Lochinvar & A.O. Smith 100112011 Burner Gasket
Your Rating
Customer Questions
What maintenance is required for the Lochinvar & A.O. Smith 100112011 Burner Gasket?

Inspect the burner gasket during routine boiler or water heater servicing for cracks, warping, or heat damage. Replace it whenever signs of wear appear to maintain proper sealing. Ensure correct installation torque and alignment to prevent gas or combustion leaks.

What are common issues with the Lochinvar & A.O. Smith 100112011 Burner Gasket?

  • Gasket hardening from prolonged heat exposure.
  • Cracking or tearing causing combustion leaks.
  • Poor sealing leading to pressure loss.
  • Misalignment during placed.
  • Deformation after repeated heating cycles.
  • Burn marks indicating overheating or improper combustion.

Installation Steps

Step 1: Turn off gas supply and electrical power to the system to prevent fire or shock hazards.

Step 2: Allow burner assembly to cool completely before servicing.

Step 3: Remove burner access panel and carefully detach the burner assembly.

Step 4: Remove old gasket and clean mating surfaces to ensure a proper seal.

Step 5: Position new gasket evenly, ensuring correct alignment with burner and housing.

Step 6: Reinstall burner assembly and tighten fasteners uniformly.

Step 7: Restore gas and power, then check for leaks and verify stable ignition.