Supco BC7070 Blower Control 0 to 4-Min 0.2A 24 VAC

Special Price $60.09 Regular Price $69.10
In stock
SKU
BC7070
The Supco BC7070 Blower Control is a time delay relay that is used to improve the efficiency of an HVAC system by controlling the blower fan operation. It is SPST relay configuration in this case provides significant improvement in energy efficiency, and avoids premature component damage ensuring optimal air circulation for residential and light commercial HVAC equipment needing controlled blower timing. It operates at 24V AC and has adjustable on/off delays from 0-240 seconds or 0-4 minutes for precise airflow control in furnaces, air handlers and heat pump systems, it delays the blower activation during heating cycles to maximize heat exchanger warmth transfer and extend post cycle operation to reduce residual heat waste.
https://www.partshnc.com/media/catalog/product/b/c/bc7070.jpg

Specifications

  • Type: Blower Control
  • Time Range: 0-4 Min
  • Current: 0.2A
  • Voltage: 24 VAC

PRODUCT OVERVIEW:
Regulates the timing of a furnace blower's operation by introducing adjustable delays at the beginning and end of the heating cycle. The Supco BC7070 Blower Control is a Genuine OEM Supco control module that coordinates blower activation and shutdown to support more efficient heat distribution. Its adjustable timing settings allow the blower sequence to be matched to the requirements of the heating system.

DELAY ADJUSTMENT:
Separate adjustable settings govern blower start and stop delays, each covering a range of 0 to 240 seconds. The start delay allows the heat exchanger time to warm before air circulation begins, while the stop delay keeps the blower operating after the heating demand ends. These independent adjustments help establish the intended airflow sequence during a heating cycle.

RELAY SWITCHING:
An SPST relay provides the electrical switching connection for controlling the blower circuit. The module uses a 24 VAC control supply to operate its timing and switching functions. Correct terminal connections and relay operation are important for ensuring that the blower responds to the programmed delay settings.

REPLACEMENT GUIDELINES:
A faulty Supco BC7070 Blower Control may need replacement when its timing adjustments no longer produce consistent blower operation, the relay fails to switch the connected circuit, or the module shows visible electrical damage. Control failure can disrupt the blower sequence and affect heat circulation through the system. An HVAC service technician can test the 24 VAC supply, inspect the control wiring and relay output, and install the replacement with the correct electrical connections.

COMMON SIGNS OF FAILURE:
Blower starts before the heating cycle is established

Fan continues running longer than the set delay

Blower fails to start during a heating demand

Air circulation stops inconsistently

Timing adjustments produce no noticeable change

EQUIPMENT COMPATIBILITY:
The Supco BC7070 Blower Control is a Genuine OEM Supco control intended for heating systems requiring this specific blower-delay module or its identified replacement equivalent, F7070. Its application depends on the system's 24 VAC control circuit, SPST relay requirements, and blower timing arrangement. Compare the existing control designation and wiring configuration with the equipment's control specifications before installation.

TECHNICAL SPECIFICATIONS:
Brand: Supco
Part Number: BC7070
Product Type: Blower Control
Control Voltage: 24 VAC
Blower On Delay: Adjustable, 0–240 Seconds
Blower Off Delay: Adjustable, 0–240 Seconds
Relay Contact Configuration: SPST
Replacement Part Number: F7070
Equipment Type: Heating System

Write Your Own Review
You're reviewing:Supco BC7070 Blower Control 0 to 4-Min 0.2A 24 VAC
Your Rating
Customer Questions
What maintenance is required for the Supco BC7070 Blower Control?

Regularly inspect the blower control for dust, debris, or loose connections. Ensure electrical terminals are secure and clean to prevent arcing. Check for proper timing settings and replace worn components carefully to maintain safe and consistent operation.

What are common issues with the Supco BC7070 Blower Control?

  • Inconsistent blower activation timing.
  • Electrical connection faults.
  • Relay sticking or failure.
  • Intermittent operation due to worn internal components.

What does the 24 VAC rating indicate on the Supco BC7070 time-delay control?

The 24 VAC rating identifies the control's required operating voltage. The HVAC control circuit must provide the specified voltage to support proper operation of the time-delay control.

What could cause an HVAC blower to start or stop at the wrong time?

Incorrect timing can result from a faulty delay control, wiring problems, or signals from other control components. Comparing the actual blower sequence with the equipment's operating requirements can help identify where the timing problem originates.

What should I compare before ordering Supco BC7070 for my HVAC system?

Check the manufacturer's parts information and compare it with Supco part number BC7070. The listed electrical requirements are 24 VAC and 0.2A, while the adjustable delay range is 0 to 4 minutes. These specifications should match the intended control application.

When is replacement of a blower time-delay control worth considering?

Replacement may be appropriate when testing confirms that the control does not maintain its intended delay, fails to respond to the operating signal, or causes inconsistent blower sequencing. A technician should distinguish a control failure from problems elsewhere in the circuit.

How can the 0-to-4-minute range be used when configuring the Supco BC7070?

The adjustment range allows the blower delay to be set within the control's available limits. The appropriate setting depends on the HVAC system's control sequence and manufacturer instructions, ensuring that fan operation follows the intended timing.

Installation Steps

Step1: Turn off power to the HVAC system before installation.

Step2: Locate the blower control area inside the appliance.

Step3: Mount the blower control securely using the provided mounting holes.

Step4: Connect the wiring to the appropriate terminals according to the system wiring diagram.

Step5: Set the desired delay time.