Bard HVAC 8402-064BX Limit Control L140-30°F
Specifications
- Type: Limit Control
Loyalty ProgramProduct Overview:
Protects HVAC equipment from excessive operating temperatures by monitoring heat levels and automatically interrupting the electrical circuit when the specified temperature limit is reached. The Bard HVAC 8402-064BX Limit Control L140-30 is a genuine OEM temperature safety control designed for automatic limit switching in heating equipment. Its L140-30 operating designation supports temperature-responsive circuit interruption and automatic reset functionality to help protect connected equipment from overheating.
Temperature Limit Control:
Monitors temperature conditions and changes its electrical contact state when the designated limit is reached. This switching response allows the control to interrupt the associated equipment circuit when the specified temperature threshold is encountered.
Equipment Protection Operation:
Provides a temperature-based interruption function within the equipment's operating sequence. By responding at its designated limit, the control helps prevent continued operation under temperature conditions that exceed the intended operating range.
Replacement Guidelines:
Replace the existing 8402-064BX Limit Control when it no longer provides the required temperature-limit response. A qualified technician should disconnect electrical power and follow the equipment's service procedures before removing the existing component. Inspect the mounting arrangement and electrical connections, then install the replacement according to the specified equipment requirements. After installation, verify the limit control's switching operation.
Common Failure Symptoms:
Equipment Compatibility:
The Bard HVAC 8402-064BX Limit Control L140-30 is an OEM replacement intended for equipment requiring this specific limit-control configuration. Before purchasing, verify the existing part number and compare the control arrangement, mounting configuration, and electrical connections with the replacement. Confirm that the L140-30 designation matches the equipment's requirements to avoid ordering an unsuitable component.
Technical Specifications:
Part Number: 8402-064BX
Brand: Bard HVAC
Component Type: Limit Control
Control Designation: L140-30
Step 1: Turn off power to the HVAC system to prevent electric shock.
Step 2: Open the control panel and locate the existing limit control.
Step 3: Disconnect all wiring from the old limit control.
Step 4: Remove the old control and mount the new unit in the same position.
Step 5: Reconnect wiring according to the original configuration.
Step 6: Restore power and test the system to ensure the limit control operates correctly.