Facebook Pixel

Kulthorn AZA0413YK1 Compressor Mbp Lst 1/6Hp 115V

Special Price $318.54 Regular Price $353.57
In stock
SKU
AZA0413YK1

The Kulthorn AZA0413YK1 Compressor Mbp Lst 1/6Hp 115V is a high-performance component intended for HVAC (Heating, Ventilation, and Air Conditioning) applications. With a power output of 1/6 horsepower and 115-volt operation, this compressor is appropriate for a wide range of household and commercial uses. With this compressor, appropriate temperature levels are maintained by effectively controlling the flow of refrigerant inside the system through the use of cutting-edge technology. Being compatible with various HVAC systems guarantees adaptability and smooth integration into various configurations. The compressor is a great option for preserving efficiency and comfort in interior spaces because of its small size and dependable operation. The Kulthorn AZA0413YK1 compressor's robust design and energy-efficient operation guarantee dependable performance while also assisting in lowering energy usage and providing long-term cost savings.

Manufacturer:
https://www.partshnc.com/media/catalog/product/a/z/aza0413yk1.jpg
Allows mechanical compression by using an electrically driven motor and internal compression mechanism to circulate refrigerant vapor through the cooling cycle in HVAC systems. The 1/6 HP rating represents the compressor’s motor power capacity, supporting the compression work required during operation. The 115V electrical supply used to operate the compressor motor. During operation, the compressor draws refrigerant vapor into its internal mechanism, compresses it, and delivers the pressurized vapor onward through the refrigeration circuit.

Cooling Cycle Support:
Conditions required to maintain the refrigeration cycle and its internal mechanism changes the condition of incoming refrigerant vapor. Preparing it for continued circulation within the cooling process. This compression activity provides the pressure relationship necessary for the refrigeration cycle to proceed in an organized sequence, allowing the compressor to perform its designated role throughout normal cooling operation.

Refrigerant Flow:
Refrigerant vapor follows a defined route across the compression assembly. Vapor enters through the suction opening, moves through the internal compression area, and exits through the discharge opening. The arrangement of these passages governs the direction of refrigerant movement within the compressor and maintains a consistent flow path between its inlet and outlet.

Replacement Guidelines:
Replacement requires matching Kulthorn AZA0413YK1 1/6HP Compressor 115V MBP LST capacity, voltage requirement, refrigeration application, physical configuration, connection arrangement, and equipment specifications. The replacement should also suit the existing refrigeration circuit and operating conditions.

Common Failure Symptoms:

  • Reduced cooling performance.
  • Increased compressor operating noise.
  • Excessive vibration.
  • Irregular startup behavior.
  • Elevated operating temperature.
  • Inconsistent refrigerant circulation.
  • Unstable compressor operation.
  • Irregular electrical performance.

Equipment Compatibility:
The Kulthorn AZA0413YK1 Compressor is intended to integrate with refrigeration equipment requiring the corresponding compressor configuration. Verify the equipment model, compressor specifications, electrical supply, refrigeration application, connection arrangement, and manufacturer’s documentation before purchasing.

Technical Specifications:
Brand: Kulthorn
Part Number: AZA0413YK1
Product Type: Compressor
Horsepower: 1/6 HP
Voltage: 115V
Application: MBP LST

Write Your Own Review
You're reviewing:Kulthorn AZA0413YK1 Compressor Mbp Lst 1/6Hp 115V
Your Rating
Customer Questions
What maintenance is required for the Kulthorn AZA0413YK1 Compressor?

Inspect electrical connections, refrigerant levels, and mounting bolts regularly to ensure stable compressor performance. Clean surrounding areas to prevent dust and debris from affecting airflow and cooling efficiency. Monitor for unusual noise or overheating and address issues promptly. Always disconnect power before servicing to prevent electrical hazards.

What are common issues with the Kulthorn AZA0413YK1 Compressor?

  • Failing to start.
  • Overheating during operation.
  • Excessive vibration or noise.
  • Electrical connection fault.

What role does the compressor play in the refrigeration sequence?

The AZA0413YK1 performs the compression stage, conditioning refrigerant vapor for continued movement through the connected refrigeration circuit.

Why does a refrigeration compressor have separate suction and discharge sides?

The suction side provides the entry path for refrigerant vapor from the low-pressure portion of the circuit, while the discharge side carries compressed vapor onward through the refrigeration circuit.

How does compressor power support refrigeration operation?

Compressor motor power provides the mechanical input needed to operate the internal compression mechanism and process refrigerant vapor during the cooling cycle.

What happens to refrigerant vapor during the compression stage?

Compression raises the refrigerant vapor pressure, creating the pressure difference needed to move refrigerant through the connected refrigeration circuit.

How does the suction side interact with the low-pressure portion of the circuit?

It provides the entry path for refrigerant vapor entering the compressor from the low-pressure portion of the refrigeration circuit.

Installation Steps

Step1: Disconnect power and verify zero voltage for safety.

Step2: Recover refrigerant using approved recovery equipment.

Step3: Disconnect wiring and refrigerant lines, then remove mounting bolts.

Step4: Install the new compressor with vibration grommets and secure hardware.

Step5: Reconnect lines, replace the filter drier, and evacuate the system.

Step6: Recharge with specified refrigerant, restore power, and test for leaks and proper operation.