Resideo AT150F1030 Transformer 208-277-480V 50VA

Special Price $59.77 Regular Price $68.73
In stock
SKU
AT150F1030
Resideo AT150F1030 Transformer is a 50VA reliable control equipment that is used to step down high voltages 208/277/480VAC to usable control voltages for HVAC systems. Equipped with 9” lead wires that are durable, it provides an uninterrupted power supply to thermostats, gas valves, relays and other control parts in residential and commercial HVAC system applications. This transformer is perfect for use in air handlers, furnaces, rooftop units, and zone control panels and allows for the proper operation of the system and increased safety through the isolation of control circuits. The high-quality construction provides long-term performance for HVAC professionals and low-voltage power transformation in harsh conditions.
Manufacturer:
https://www.partshnc.com/media/catalog/product/a/t/at150f1030.jpg

Specifications

  • Frequency: 60Hz
  • VA Rating: 50VA
  • Temperature Range: -20°F to 105°F
  • Height: 3.19"
  • Width: 2.19"
  • Connection Size: 9"
  • Voltage: 208/277/480V ac
  • Connection Type: Leadwires

Product Overview:
Converts incoming electrical power to a 27V secondary supply for HVAC control circuits. The Resideo AT150F1030 Panel Mount Transformer 50VA 208-277/480V PRI-27V SEC is an OEM electrical power component rated at 50 VA, with a 208–277/480V primary configuration. Its panel-mount design suits control-power applications requiring the specified primary and secondary voltages.

Electrical Voltage Conversion:
Through electromagnetic induction, a transformer transfers electrical energy between its primary and secondary windings while changing the voltage level. The primary winding receives the incoming electrical supply, while the secondary winding delivers the converted voltage to the connected circuit. This arrangement allows the transformer to provide an appropriate electrical supply for the control-side components associated with the equipment.

Control Power Distribution:
Within HVAC equipment, the transformer connects the incoming electrical supply with the control circuit through its primary and secondary sides. The resulting secondary supply supports connected control components during the equipment operating cycle. This places the transformer within the electrical pathway between the equipment supply and the components that depend on the control voltage.

Replacement Guidelines:
Selecting a suitable transformer requires matching the electrical requirements of the existing HVAC control circuit with the specified transformer configuration. The Resideo AT150F1030 Panel Mount Transformer 50VA 208-277/480V PRI-27V SEC is appropriate where the equipment requires its listed primary and secondary voltage arrangement and power capacity. Confirming these requirements helps maintain the intended control-power arrangement.

Common Failure Symptoms:

  • Connected control components may not receive the required electrical supply.
  • The HVAC control circuit may fail to receive its expected secondary voltage.
  • Control-side operation may become unavailable when the transformer does not provide the required output.
  • Equipment controls dependent on the transformer may become inactive.

Equipment Compatibility:
Resideo AT150F1030 Panel Mount Transformer 50VA 208-277/480V PRI-27V SEC is intended for HVAC equipment requiring a panel-mount transformer with the specified electrical configuration. It applies to control-power arrangements calling for the listed primary voltage, secondary voltage, and power capacity.

Technical Specifications:
Brand: Resideo
Part Number: AT150F1030
Type: Panel Mount Transformer
Capacity: 50VA
Primary: 208-277/480V
Secondary: 27V

Write Your Own Review
You're reviewing:Resideo AT150F1030 Transformer 208-277-480V 50VA
Your Rating
Customer Questions
What is the Resideo AT150F1030 transformer used for?

It converts incoming electrical voltage to the secondary level required by an HVAC control circuit.

What are the primary and secondary sides of a transformer?

The primary receives the incoming supply, while the secondary delivers the transformed voltage to the connected circuit.

Why must transformer capacity match the control circuit?

The transformer must provide sufficient electrical capacity to meet the connected circuit's specified requirements.

What signs may indicate a faulty HVAC transformer?

Loss of control power, intermittent operation, or visible overheating may indicate a transformer problem.

How should the AT150F1030 transformer be inspected?

Check for physical damage, overheating, and loose connections. Have a qualified technician perform electrical testing.