952-2600-941

The replacement motor, 230/460V3ph 1 1/2 HP 1725 RPM, is designed especially for the Aurora Pump 952-2600-941. This three-phase, 1.5-horsepower motor rotates at 1725 revolutions per minute. This motor converts electrical energy into mechanical energy, which rotates the pump's impeller to move fluids around HVAC systems. This replacement motor is compatible with a wide range of centrifugal pumps used in HVAC applications, including condenser water loops, heating boilers, and chilled water systems. This compatible substitute can be used to replace a failing motor, maintain the effective fluid circulation system in your HVAC system, and repair pump functionality. This helps to preserve maximum efficiency.

Manufacturer:
https://www.partshnc.com/media/catalog/product/9/5/952-2600-941.jpg

Pump systems use dedicated motors to provide the mechanical drive required by connected pumping equipment. The Aurora Pump 952-2600-941 is a pump motor that supplies rotational input to the connected pump assembly. This mechanical output supports the pump's intended operation during system operation.

Electrical Power for Pump Operation:
The pump motor is specified for 230-460V, 3-phase electrical operation and has a 1-1/2 HP rating. The voltage and phase define the electrical supply configuration, while the horsepower identifies the motor's specified power rating. These characteristics form part of the motor's electrical and power configuration.

Pump Drive and Rotational Performance:
The pump motor converts electrical input into rotational movement for the connected pumping assembly. Its 1725 RPM rating identifies the specified shaft speed, defining the motor's rotational operating characteristic. The rotating shaft provides the mechanical input required by the pump during operation.

Replacement Guidelines:
Replacement may be appropriate when the existing Aurora Pump 952-2600-941 no longer provides the required mechanical drive or develops irregular shaft rotation. Before ordering, compare the existing part number with the required pump configuration and specified motor characteristics.

Common Failure Symptoms:

  • The shaft develops irregular movement during operation.
  • The motor produces unusual sounds while running.
  • Noticeable vibration develops during operation.
  • The connected pump exhibits inconsistent movement.
  • Visible physical damage appears on the motor assembly.

Equipment Compatibility:
The Aurora Pump 952-2600-941 Pump Motor should be selected for pump applications requiring a 1-1/2 HP, 230-460V, 3-phase motor rated at 1725 RPM. Before purchasing, confirm the existing part number, required horsepower, speed, voltage, phase, and other pump system requirements.

Technical Specifications:
Part Identification:
Brand: Aurora Pump
Part Number: 952-2600-941
Product Type: Pump Motor

Electrical:
Voltage: 230-460V
Phase: 3-Phase

Mechanical:
Horsepower: 1-1/2 HP
Speed: 1725 RPM

Write Your Own Review
You're reviewing:Aurora Pump 952-2600-941 1-1/2 HP Pump Motor 1725 RPM 230-460V 3-Phase
Your Rating
Customer Questions
What maintenance is required for the Aurora Pump 952-2600-941 Pump Motor?

Regularly inspect bearings and apply proper lubrication to reduce wear. Check electrical connections for tightness and signs of overheating. Keep the motor clean and well-ventilated to prevent overheating. Follow lockout procedures for safe servicing.

What are common issues with the Aurora Pump 952-2600-941 Pump Motor?

  • Bearing failure leading to noise and friction.
  • Overheating under load during continuous operation.
  • Electrical winding faults causing power loss or burnouts.
  • Vibration and misalignment resulting in unstable performance.
  • Phase imbalance issues affecting efficiency.

What type of motor is the Aurora Pump 952-2600-941?

The Aurora Pump 952-2600-941 is a pump motor designed to provide rotational mechanical drive to a connected pumping assembly.

How does the 952-2600-941 support pump operation?

The motor converts electrical input into shaft rotation, providing the mechanical input required by the connected pump.

What does the 1725 RPM rating identify on the pump motor?

The 1725 RPM rating identifies the motor's specified shaft speed and defines an important mechanical characteristic for matching the pump motor configuration.

What electrical configuration is associated with the 952-2600-941?

The motor is specified for 230-460V, 3-phase operation with a 1-1/2 HP rating.

What should be matched before purchasing the Aurora Pump 952-2600-941?

Compare the existing part number, required horsepower, speed, voltage, phase, and pump configuration before ordering.

Installation Steps

Step 1: Turn off power supply and apply lockout/tagout for safety.

Step 2: Mount motor on compatible pump base, ensuring proper shaft alignment.

Step 3: Connect wiring per phase electrical diagram carefully.

Step 4: Secure coupling, check rotation direction by hand before energizing.

Step 5: Tighten all mounting bolts and recheck alignment precisely.

Step 6: Restore power, test under load, and monitor vibration levels.

Step 7: Ensure motor operates within rated temperature and current limit.