Facebook Pixel

Nordyne 903111 Inducer Blower Assembly

Special Price $229.81 Regular Price $255.09
In stock
SKU
903111
Nordyne 903111 Inducer Blower Assembly, an essential component meant to ensure proper combustion through enhanced air flow in the burner assembly. The high-efficiency induction fan helps to remove exhaust gases from the furnace and maintain optimal performance by creating a strong draft. It is found in gas furnaces and other heating systems that prevent dangerous gas build-up while promoting efficient heating at the same time. Managing exhaust flow effectively with this model reduces overheating risks and extends furnace life as well.
https://www.partshnc.com/media/catalog/product/9/0/903111.jpg

Specifications

  • Type: Inducer Blower Assembly
  • Voltage: 115V
  • Phase: 1PH
  • Speed: 3000 RPM
  • Frequency: 60 Hz
Manufacturer Name: Nordyne
Product Number: 903111
OEM Part Number: 903111
Product Description: Inducer Blower Assembly
Weight:5.12lbs/2322.39g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Nordyne 903111 Inducer Blower Assembly
Your Rating
Customer Questions
What maintenance is required for the Nordyne 903111 Inducer Blower Assembly?

Inspect the inducer assembly for proper airflow and secure mounting. Clean any debris from the fan and housing. Check electrical connections and motor function. Regular maintenance supports ensure proper ventilation and combustion support.

What are common issues with the Nordyne 903111 Inducer Blower Assembly?

  • Failure to start or run properly.
  • Blocked airflow affecting operation.
  • Motor noise or vibration issues.
  • Electrical faults causing inconsistent performance.

Installation Steps

Step 1: Turn off power and gas supply to unit to ensure safety.

Step 2: Remove access panel and disconnect electrical connectors and mounting screws from old inducer assembly.

Step 3: Carefully detach vent connections and remove defective blower assembly.

Step 4: Position new inducer blower assembly and secure mounting screws.

Step 5: Reconnect wiring harness and vent connections tightly.

Step 6: Restore power and test operation for proper draft; check for leaks or unusual noise.