Loyalty ProgramStep1: Turn off power and unplug the refrigeration unit before starting.
Step2: Recover R-290 refrigerant per safety regulations before opening the system.
Step3: Remove access panels and disconnect electrical leads and refrigeration lines from the old compressor.
Step4: Remove the old compressor and clean the mounting area.
Step5: Install the new compressor, reconnect lines with proper brazing, and tighten fittings.
Step6: Evacuate, recharge with R-290, restore power, and test for correct operation and leaks.