The Cozy Heaters 84170 Fan Switch is a unique device that controls the fan depending on the temperatures set in heating and ventilating systems. With a temperature range of 40°F for it to turn on and 130°F to turn off, this Switch effectively controls the fan's power. It is normally surface mounted and this makes it easier to install in different HVAC systems. Mainly installed in heating systems, the fan switch turns the fan on to spread heat when the temperatures are low and below 40°F. When the temperature gets to 130°F the switch is triggered to shut off the fan to avoid overheating.
https://www.partshnc.com/media/catalog/product/8/4/84170.jpg

Specifications

  • Weight:0.02 Lbs
  • Type: Switch
  • Material: Rubber
  • Temperature Range: 40°F(Turn on), 130°F(Turn off)
  • Mounting:Surface Mount
Manufacturer Name: Cozy Heaters
Product Number: 84170
OEM Part Number: 84170
Product Description: F130-40F Fan Switch
Weight:0.02lbs/9.07g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Cozy Heaters 84170 Fan Switch F130-40F
Your Rating
Customer Questions
What maintenance is required for the Cozy Heaters 84170 Fan Switch?

Inspect the fan switch regularly for secure electrical connections and signs of overheating or corrosion at the terminals. Keep the surrounding area clean to prevent dust buildup that can affect switching performance.

What are common issues with the Cozy Heaters 84170 Fan Switch?

  • Fan fails to turn on at low temperature setpoint.
  • Switch does not shut off at high temperature limit.
  • Intermittent fan cycling or inconsistent operation.
  • Electrical contact wear causing delayed response.
  • Temperature sensing failure leading to incorrect switching.

Installation Steps

Step 1: Turn off power at breaker and confirm no voltage for safety always.

Step 2: Remove heater access panel and locate the existing fan switch.

Step 3: Document wiring positions, then carefully disconnect old switch terminals.

Step 4: Install new switch matching terminals exactly.

Step 5: Secure switch, reassemble panel, restore power, and test fan operation.

Step 6: Verify thermostat response and ensure fan cycles correctly after installation.