Facebook Pixel

Asco 8220G025 2-Way N/C Steam/Hot Water Brass Solenoid Valve 1" NPT 125 PSI 120V/60Hz-110V/50Hz AC

Special Price $1,006.42 Regular Price $1,117.12
In stock
SKU
8220G025
The ASCO 8220G025 2-Way Solenoid Valve Steam/Hot Water Brass is used to control the flow of fluids through the piping in HVAC systems. This is a normally closed valve with a 1" NPT body that is rated at 125 PSI and is energised by 120 V/60Hz or 110 V/50Hz power currents to open when needed and permits the passage of fluid as needed by the system. It is applied in heating and steam distribution circuits where flow actuation should be controlled to regulate the temperature. This fluid control system responds to electrical signals to control the flow.
Manufacturer:
https://www.partshnc.com/media/catalog/product/8/2/8220g025_asco_partshnc.jpg
Manufacturer Name: ASCO
Product Number: 8220G025
OEM Part Number: 8220G025
Product Description: 120/60110/50Vac 1" Npt. 2 Way N.C. Steam/Hot Water Brass Solenoid Valve 125 Psi
Weight:6lbs/2721.55g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Asco 8220G025 2-Way N/C Steam/Hot Water Brass Solenoid Valve 1" NPT 125 PSI 120V/60Hz-110V/50Hz AC
Your Rating
Customer Questions
What maintenance is required for the Asco 8220G025 Solenoid Valve?

Regularly inspect the valve for leaks, corrosion, or debris buildup. Test electrical connections and ensure proper coil operation. Clean internal components if needed and verify smooth valve movement. Follow safety precautions when handling pressurized steam or hot water.

What are common issues with the Asco 8220G025 Solenoid Valve?

  • Failure to open or close fully.
  • Coil burnout or electrical faults.
  • Leaks around seals or connections.
  • Sticking due to debris or mineral buildup.

Installation Steps

Step 1: Turn off power and steam/water supply; depressurize line fully before installation.

Step 2: Verify voltage, flow direction arrow, and compatible piping size.

Step 3: Install valve inline with correct orientation; use thread sealant on fittings.

Step 4: Tighten connections, restore power, and test coil energization for proper opening/closing.

Step 5: Check for leaks, ensure grounding and avoid operating without fluid flow for safety.