Facebook Pixel

Burnham Boiler 80160738 SPST Pressure Switch 4" WC

Special Price $98.01 Regular Price $112.71
In stock
SKU
80160738
The Burnham New Yorker 80160738 SPST Pressure Switch is an essential element of HVAC systems, which is used for pressure control in the system successfully. It measures 4" in size, and has a 24 volt power supply and works like an SPST switch to give consistent performance in heating and cooling applications. This type of switch detects pressure changes within the system and responds to ensure that the system’s performance and safety are at optimum. It is widely used in boiler applications, furnaces, and other related applications based on heating, ventilation, and air conditioning equipment where pressure control is critical for process performance.
https://www.partshnc.com/media/catalog/product/8/0/80160738.jpg

Specifications

  • Size: 4"
  • Type: Pressure Switch
  • Connection Type: SPST
  • Voltage: 24V
  • Weight: 0.16 Lbs
Manufacturer Name: BURNHAM NEW YORKER
Product Number: 80160738
OEM Part Number: 80160738
Product Description: .4"Wc Spst Pressure Switch
Weight:0.16lbs/72.57g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

 

Write Your Own Review
You're reviewing:Burnham Boiler 80160738 SPST Pressure Switch 4" WC
Your Rating
Customer Questions
What maintenance is required for the Burnham Boiler 80160738 Pressure Switch?

Check the switch and tubing for blockages or damage that could affect pressure sensing. Ensure all electrical connections are firm and corrosion-free. Test switching function regularly. Proper upkeep supports maintain safe pressure control.

What are common issues with the Burnham Boiler 80160738 Pressure Switch?

  • Failure to respond at designated pressure levels.
  • Obstructed tubing affecting pressure detection.
  • Contact wear causing unaccurate switching.
  • Electrical issues leading to malfunction.
  • Erratic activation during system operation.

Installation Steps

Step 1: Turn off power and gas supply to the system.

Step 2: Locate and remove the faulty pressure switch.

Step 3: Disconnect wiring carefully, noting positions.

Step 4: Mount the new switch securely in place.

Step 5: Reconnect wires to matching terminals.

Step 6: Attach tubing and ensure airtight fit.

Step 7: Restore power and test operation; check for leaks or faults.