7855596

The Viessmann 7855596 Radial Fan NRG118 B1Ha/B1Ka is a critical component that enhances the performance of HVAC systems. By effectively moving air throughout the system, this radial fan maintains steady circulation and controls temperature. This improves the performance of these systems, encouraging dependability and energy efficiency. The exhaust fan minimizes energy consumption and contributes to the maintenance of comfortable indoor environments by efficiently spreading warm or cooled air throughout the space. The Viessmann 7855596 Radial Fan is a solid option for enhancing the functionality and effectiveness of HVAC systems, which will ultimately result in increased user comfort and cost savings due to its sturdy design and accurate engineering.

https://www.partshnc.com/media/catalog/product/7/8/7855596_viessmann_partshnc.jpg

Specifications

  • Type: Radial Fan
  • Model: NRG118
  • Usage: B1HA/B1KA

PRODUCT OVERVIEW:
Delivers the combustion airflow required for burner operation in designated Viessmann heating equipment. The Viessmann 7855596 Radial Fan NRG118 B1HA/B1KA is an OEM replacement component designed to support the air supply needed during the combustion cycle. Its radial fan design helps maintain consistent airflow within the burner assembly to support normal heating operation.

COMBUSTION AIRFLOW:
Moves air through the combustion system to provide the airflow required for the fuel-burning process. The rotating fan mechanism generates the movement needed to supply air during operating cycles. Consistent airflow helps the burner maintain the conditions required for proper combustion and reliable heat production.

RADIAL FAN ASSEMBLY:
Features an NRG118 radial fan configuration designed for integration into the specified burner assembly. Its dedicated construction provides the airflow-generating component within the combustion system. The fan's arrangement supports its connection with the associated equipment components and the required air passage.

REPLACEMENT GUIDELINES:
Replace the Viessmann 7855596 Radial Fan when the fan fails to operate, produces unusual noise, or causes combustion-related faults. Have a licensed heating contractor inspect the burner assembly, install the fan, and verify safe boiler operation.

COMMON SIGNS OF WEAR:

  • Fan fails to start.
  • Unusual noise during fan operation.
  • Insufficient combustion airflow.
  • Repeated burner startup interruptions.
  • Visible damage to the fan assembly.

EQUIPMENT COMPATIBILITY:
The Viessmann 7855596 Radial Fan NRG118 B1HA/B1KA is an OEM component specified for applicable Viessmann Vitodens 100-W B1HA and B1KA models. The correct application depends on the equipment's specific model and production configuration. Verify the complete model and serial number, along with the original part number, against manufacturer documentation before ordering.

TECHNICAL SPECIFICATIONS:
Brand: Viessmann
Part Number: 7855596
Product Type: Radial Fan
Fan Designation: NRG118
Equipment Series: B1HA / B1KA

Write Your Own Review
You're reviewing:Viessmann 7855596 Radial Fan NRG118 B1HA/B1KA
Your Rating
Customer Questions
What maintenance is required for the Viessmann 7855596 Radial Fan?

Regularly clean the fan blades and housing to remove dust and debris that could reduce airflow. Inspect the motor and bearings for wear and lubricate if needed. Ensure secure mounting and proper alignment to prevent vibration. Routine checks extend fan life and maintain system efficiency.

What are common issues with the Viessmann 7855596 Radial Fan?

  • Reduced airflow due to dust or debris buildup.
  • Unusual humming or vibration noises.
  • Intermittent or failed motor operation.
  • Electrical connection faults.

What is the Viessmann 7855596 Radial Fan used for?

The Viessmann 7855596 Radial Fan provides mechanical air movement through the associated air path for its intended application.

How does the 7855596 Radial Fan move air?

The radial fan uses rotational movement of its fan assembly to generate airflow through the connected air path.

Which application is the Viessmann 7855596 Radial Fan associated with?

The Viessmann 7855596 is associated with the NRG118 B1HA/B1KA application.

What signs may indicate that the 7855596 Radial Fan needs replacement?

Reduced air movement, irregular rotation, unusual mechanical sounds, excessive vibration, or the fan stopping during operation may indicate that replacement is appropriate.

What should I check before selecting the 7855596 Radial Fan?

Before purchasing, confirm the existing fan's part number, radial fan configuration, NRG118 B1HA/B1KA application, and other applicable system requirements.

What is the primary function of the Viessmann 7855596?

It circulates combustion air through the boiler, supporting the airflow required for proper burner operation.

What problems can occur if the Viessmann 7855596 becomes faulty?

A damaged fan can cause insufficient airflow, ignition problems, burner shutdowns, or interrupted heating operation.

How does the Viessmann 7855596 differ from a circulation pump?

A radial fan moves air through the combustion system, while a circulation pump moves water through the heating circuit.

Where is the Viessmann 7855596 used within the heating system?

It is installed within the boiler's combustion air assembly in compatible B1HA and B1KA series equipment.

What information should be checked before ordering the Viessmann 7855596?

Verify the existing part number, complete boiler model, and fan configuration to confirm compatibility with the original assembly.

Installation Steps

Step1: Turn off power to the boiler/ HVAC unit at the breaker and verify it’s off.

Step2: Remove the access panel and disconnect the old fan’s wiring harness.

Step3: Remove mounting screws and take out the old radial fan assembly.

Step4: Install the new radial fan in the same orientation and secure with screws.

Step5: Reconnect the wiring harness to matching terminals.

Step6: Replace the access panel, restore power, and test fan operation.