The Advanced Distributor Products 76715000 Electrode Flame Sensor is a crucial safety component in gas-fired HVAC systems. It safeguards against gas leaks and potential explosions by detecting the presence of a flame during operation. The sensor essentially acts as a watchful eye, ensuring the gas supply is only active when a flame is established. Made from durable materials to withstand high temperatures ranging from -40°C to 100°C, it's compact in size at roughly 1 inch long by 0.2 inches wide and 0.02 to 0.1 inches thick, allowing for easy installation within compatible HVAC units.
https://www.partshnc.com/media/catalog/product/7/6/76715000_advanced-distributor-products_partshnc.jpg

Specifications

  • Weight:0.06lbs
  • Temperature: -40°C to 100°C
  • Size: 1 Inch to 0.2 Inch
  • Thickness: 0.02 Inch to 0.1 Inch
Manufacturer Name: Advanced Distributor Products
Product Number: 76715000
OEM Part Number: 76715000
Product Description: Electrode/Flame Sensor
Weight:0.06lbs/27.22g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Advanced Distributor Products 76715000 Electrode/Flame Sensor
Your Rating
Customer Questions
What maintenance is required for the Advanced Distributor Products 76715000 Electrode/Flame Sensor?

Clean the electrode regularly to remove carbon buildup and ensure essential flame sensing. Inspect wiring connections for corrosion or looseness and tighten as needed. Schedule periodic inspection of ignition performance to maintain safe operation.

What are common issues with the Advanced Distributor Products 76715000 Electrode/Flame Sensor?

  • Carbon buildup on electrode causing weak or no flame signal.
  • Faulty wiring or loose connections leading to intermittent ignition failure.
  • Corroded sensor surface reducing accuracy.
  • Misalignment or wear causing inconsistent flame detection.

Installation Steps

Step 1: Turn off furnace power and gas supply; allow unit to cool.

Step 2: Open burner compartment and locate old flame sensor.

Step 3: Remove mounting screw and gently pull out sensor.

Step 4: Install new sensor in same position, ensuring rod sits in flame path.

Step 5: Reconnect wire, secure screw, restore power and gas.

Step 6: Test ignition and confirm stable flame signal.