Hydrolevel 711CF Low‑Water Cutoff Sight Glass Mounting 35 PSI 120V

Special Price $585.38 Regular Price $649.77
In stock
SKU
711CF

The Hydrolevel 711CF is a 120-volt low water cut-off (LWO) switch with a sight glass and a 35-psi pressure rating, specifically developed for hydronic heating systems. It serves as an essential safety mechanism to stop possible water shortage-related boiler damage. A mercury tilt switch and a float mechanism are both included in the LWO switch. When the boiler's water level falls below a safe threshold, the float activates the tilt switch, which turns off the boiler's electricity. So, the boiler is kept from running without adequate water circulation, protecting it from overheating and probable component failure. The sight glass, a clear window on the side of the apparatus, makes it possible to see the boiler's water level.

Manufacturer:
https://www.partshnc.com/media/catalog/product/7/1/711cf.jpg
Manufacturer Name: Hydrolevel
Product Number: 711CF
OEM Part Number: 711CF
Product Description: 120Vlwco,Sightglmtg,35#
Weight:12.75lbs/5783.3g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Hydrolevel 711CF Low‑Water Cutoff Sight Glass Mounting 35 PSI 120V
Your Rating
Customer Questions
What maintenance is required for the Hydrolevel 711CF Low-Water Cutoff?

Inspect sight glass and low-water cutoff assembly for scale buildup, leaks, and loose electrical connections. Clean glass components and test cutoff operation under controlled conditions. This maintenance ensures safe boiler operation and prevents dry-fire damage.

What are common issues with the Hydrolevel 711CF Low-Water Cutoff?

  • False low-water cutoff trips due to scale buildup or sensor fouling.
  • Sight glass blockage or discoloration affecting water level visibility.
  • Intermittent electrical operation caused by loose wiring or contact wear.
  • Leaks at mounting points or gasket degradation over time.

Installation Steps

Step 1: Shut off boiler power and allow system to cool.

Step 2: Remove existing old low-water cutoff assembly and clean mounting surfaces.

Step 3: Install new low-water cutoff tapping using approved sealant.

Step 4: Connect wiring per control diagram, ensuring secure grounding.

Step 5: Restore water pressure gradually and refill boiler to operating level.

Step 6: Test low-water cutoff operation and check safe burner shutdown response.