The Nordyne 664073R 0.073" Piston controls refrigerant flow by metering the amount of liquid refrigerant entering the evaporator for the cooling process. Refrigerant passes through the precisely sized opening, creating the pressure differential required for proper expansion before circulating through connected cooling circuits. Integrated between the liquid line and evaporator, the piston establishes the required flow restriction across the HVAC equipment under varying operating conditions. Controlled refrigerant metering stabilizes system pressure, improves cooling uniformity, minimizes flow fluctuation, maintains balanced operation and ensure dependable thermal performance.
Manufacturer:
https://www.partshnc.com/media/catalog/product/6/6/664073r.jpg
Manufacturer Name: Nordyne
Product Number: 664073R
OEM Part Number: 664073R
Product Description: .073 Piston
Weight:0.02lbs/9.07g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Nordyne 664073R 0.073" Piston
Your Rating
Customer Questions
What maintenance is required for the Nordyne 664073R .073 Piston?

Regularly inspect the piston for wear, debris, or corrosion. Clean with a soft cloth and appropriate lubricant. Ensure proper installation alignment to prevent operational issues. Always follow safety protocols to avoid damage during handling.

What are common issues with the Nordyne 664073R .073 Piston?

  • Uneven wear or scoring on the piston surface.
  • Sticking or binding within the cylinder.
  • Reduced efficiency due to improper seating.
  • Noise or vibration during operation.

Installation Steps

Step 1: Turn off HVAC power and recover refrigerant safely.

Step 2: Access indoor coil or metering device and remove existing piston carefully.

Step 3: Inspect and clean distributor body and check for debris or wear.

Step 4: Install new piston in correct orientation, ensuring proper seating.

Step 5: Reassemble fittings, replace seals if needed, and torque connections.

Step 6: Evacuate system, recharge refrigerant, and verify superheat and stable cooling operation.