Facebook Pixel

Nordyne 661036R 0.036 LP Burner Orifice #36

Special Price $19.60 Regular Price $25.48
In stock
SKU
661036R
The Nordyne 661036R LP Burner Orifice 0.036 #36 is an element that controls the flow of fuel in HVAC Systems. This opening is a highly accurate meter of liquid propane to the burner, which ensures adequate combustion under normal commercial operating conditions. It is fitted in heating equipment and simply fitted in the existing fuel assembly, without changing the core design of the unit. It aids in regulated ignition and effective flame, which ensures stability in the amount of heat released and stability in the operation of the entire part that is connected.
Manufacturer:
https://www.partshnc.com/media/catalog/product/6/6/661036r.jpg
Manufacturer Name: Nordyne
Product Number: 661036R
OEM Part Number: 661036R
Product Description: .036 Lp Orifice #36
Weight:0.02lbs/9.07g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Nordyne 661036R 0.036 LP Burner Orifice #36
Your Rating
Customer Questions
What maintenance is required for the Nordyne 661036R .036 Burner Orifice?

Inspect the orifice periodically for dust, soot, or debris that may restrict gas flow. Clean gently using appropriate non-abrasive methods to preserve the accurate drill size and ensure consistent fuel delivery. Check for secure seating and signs of corrosion to maintain stable combustion performance.

What are common issues with the Nordyne 661036R .036 Burner Orifice?

  • Carbon buildup affecting combustion efficiency.
  • Corrosion or wear altering flow features.
  • Misalignment causing improper ignition.
  • Clogged orifice restricting gas flow.
  • Uneven flame or poor burner performance.

Installation Steps

Step 1: Turn off electrical power and shut off the propane gas supply to the furnace or heating appliance.

Step 2: Remove the burner access panel and locate the burner manifold assembly.

Step 3: Disconnect the burner tube as needed to access the existing #36 LP burner orifice.

Step 4: Remove the old orifice using the appropriate wrench and inspect the manifold threads.

Step 5: Install the new orifice, tightening it securely without over-torquing.

Step 6: Reassemble the burner components, restore gas and power, check for leaks with a soap-and-water solution, and verify proper burner ignition and flame characteristics.