Lochinvar & A.O. Smith 100111064 Blocked Outlet Switch 0.6"-5.0" WC

Special Price $99.92 Regular Price $114.91
Out of stock
SKU
100111064
The Lochinvar & A.O. Smith 100111064 is a Air Switch 0.6”/5.0” WC which is an important safety device employed in the gas water heaters and boilers. It checks the air pressure within the system so as to allow correct ventilation and combustion. In the case where the pressure is low or high, it goes beyond the limit of pressure range the switch turns on and turns off the system to avoid such conditions. This device provides safety, preserves efficiency and shields the equipment from possible harm. By thus maintaining a proper airflow, it supports the proper functioning thus making it very crucial for safety of HVAC systems.
https://www.partshnc.com/media/catalog/product/1/0/100111064.jpg

Specifications

  • Type: Air Switch
  • Pressure: 0.6"/5.0"WC
Manufacturer Name: Lochinvar & A.O. Smith
Product Number: 100111064
OEM Part Number: 100111064
Product Description: .6/5.0"Wc Air Switch
Weight:0.24lbs/108.86g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Lochinvar & A.O. Smith 100111064 Blocked Outlet Switch 0.6"-5.0" WC
Your Rating
Customer Questions
What maintenance is required for the Lochinvar & A.O. Smith 100111064 Blocked Outlet Switch?

Inspect the pressure sensing ports and tubing regularly for blockages or moisture buildup. Ensure all electrical connections remain tight and free from corrosion. Periodic calibration checks help maintain accurate pressure response. Proper maintenance ensures accurate system shutdown protection and prevents false trip conditions in heating equipment.

What are common issues with the Lochinvar & A.O. Smith 100111064 Blocked Outlet Switch?

  • False tripping due to restricted airflow.
  • Faulty pressure sensing or drift.
  • Cracked or blocked sensing tubing.
  • Loose electrical connections causing shutdowns.
  • Moisture intrusion affecting switch performance.
  • Delayed or inconsistent response under load.

Installation Steps

Step 1: Turn off power and gas supply; verify system is isolated before service.

Step 2: Remove access panel on the unit using the proper tool.

Step 3: Disconnect wiring from old blocked outlet switch, label wires and note positions.

Step 4: Unscrew and remove faulty switch carefully.

Step 5: Install new switch in same port, secure tightly without over-torquing.

Step 6: Reconnect wiring as per diagram or manufacturer instructions.

Step 7: Restore power, test for proper operation; check for leaks or alarms.