Facebook Pixel

Rheem-Ruud 61-104031-02 Thermal Expansion Valve (TXV) R-410A 4-Ton 3/8"

Special Price $129.25 Regular Price $148.63
In stock
SKU
61-104031-02
The Rheem-Ruud 61-104031-02 Thermal Expansion Valve is designed for the additional improvement of HVAC systems employing R-410A as the refrigerant. It has been recommended for cooling capacity of 4-ton and the inlet size is 3/8 inches. The valve helps to regulate the amount of refrigerant that is allowed to pass through the evaporator coil so as to meet the cooling load of the system. It also ensures that the right pressure and temperature is maintained within the right range hence preventing system freeze and wasteful operation. By these parameters, the valve improves energy use, the cost of operations come down, and the longevity of the HVAC equipment declines.
https://www.partshnc.com/media/catalog/product/6/1/61-104031-02.jpg

Specifications

  • Type:Thermal Expansion Valve
  • Weight:1.28lbs
  • Size:Inlet 3/8"
  • Refrigerant:R-410A
  • Capacity:4-Ton
Manufacturer Name: Rheem-Ruud
Product Number: 61-104031-02
OEM Part Number: 61-104031-02
Product Description: Expansion Valve
Weight:1.28lbs/580.6g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Rheem-Ruud 61-104031-02 Thermal Expansion Valve (TXV) R-410A 4-Ton 3/8"
Your Rating
Customer Questions
What maintenance is required for the Rheem-Ruud 61-104031-02 Thermal Expansion Valve?

Inspect valve and sensing bulb for secure mounting and proper operation. Keep system clean and replace filter-drier when contaminated or restricted. Check refrigerant charge and pressures and prevent debris buildup in the line.

What are common issues with the Rheem-Ruud 61-104031-02 Thermal Expansion Valve?

  • Valve sticking or erratic metering.
  • Incorrect superheat causing poor cooling.
  • Sensing bulb failure or poor contact.
  • Refrigerant restriction or blockages.
  • Hunting or unstable system pressures.
  • Icing or coil freeze issues.

Installation Steps

Step 1: Turn off power and recover refrigerant using HVAC equipment.

Step 2: Access the evaporator coil and locate the existing valve.

Step 3: Disconnect sensing bulb, equalizer line, and refrigerant connections.

Step 4: Remove the old valve and install the new thermal expansion valve in correct flow direction.

Step 5: Secure and insulate the sensing bulb on the suction line.

Step 6: Evacuate system, recharge refrigerant, restore power, and test for leaks and performance.