Daikin-McQuay 6025174 Four Way Valve Coil Assembly .

Special Price $44.37 Regular Price $57.68
In stock
SKU
6025174
The Daikin-McQuay 6025174 Four-Way Valve Coil Assembly is an electromagnetic control part that is used to activate the reversing valve in heat pump and air-conditioning systems. When the coil becomes energized, it create a magnetic field that move the internal valve mechanism which redirects the flow of refrigerant applied in HVAC systems. The coil is placed over the stem of the four-way reversing valve, and attached to the system control wiring by electrical leads. It is mounted on the reverse valve body on the refrigerant circuit and is the source of the electrical actuation needed to switch modes when operating the system.
Manufacturer:
https://www.partshnc.com/media/catalog/product/6/0/6025174_daikin-mcquay_partshnc.jpg

PRODUCT OVERVIEW:
Reversing valve solenoid coils generate the electromagnetic force required to shift heat pump refrigerant circuits between heating and cooling cycles. The Daikin-McQuay 6025174 Four Way Valve Coil Assembly is an OEM component designed to drive pilot valve actuation in compatible Daikin and McQuay heat pumps. Installed externally over the four-way reversing valve stem, this coil receives electrical control signals from the equipment board to reposition the pilot slider. By shifting internal pressure differentials, the unit enables seamless seasonal mode changes and consistent temperature control.

ELECTROMAGNETIC PILOT ACTUATION:
An internal insulated wire winding converts control voltage into a strong magnetic field. When the equipment thermostat requests a mode shift, the system board energizes the coil terminals, pulling the internal pilot plunger against spring force. Once electrical power is removed, the electromagnetic field collapses, allowing spring tension to return the plunger to its default position.

REFRIGERANT DIRECTION MODULATION:
Positioned on the external stem of the reversing valve, this coil governs fluid routing by controlling internal pilot pressure paths. Energizing the coil redirects high-pressure discharge gas and low-pressure suction gas to opposite sides of the main valve spool. The resulting pressure imbalance slides the main spool, shifting the refrigerant flow path between the indoor and outdoor coils to alternate between heating and cooling modes.

REPLACEMENT GUIDELINES:
Component replacement is necessary when the coil exhibits open electrical continuity, short circuits, or thermal casing breakdown. Malfunctioning reversing valve coils prevent heat pumps from switching operating modes, lock systems in default fail-safe paths, or cause control board fuse failures. Because the coil mounts externally, replacement does not require opening the sealed refrigerant circuit. Before purchasing, verify the part number and all relevant specifications against the original equipment documentation to ensure the replacement matches the system requirements.

COMMON FAILURE SYMPTOMS / COMMON SIGNS OF WEAR:

  • Heat pump system fails to switch between heating and cooling modes during a call from the thermostat.
  • Persistent chatter, loud buzzing, or mechanical humming originating from the coil housing during operation.
  • HVAC system remains stuck permanently in its default unpowered refrigerant flow direction.
  • Visible electrical burning, cracked resin casing, or melted insulation on the coil body.
  • Frequent blowing of the main 24V control circuit fuse due to an internal electrical short.

EQUIPMENT COMPATIBILITY:
The Daikin-McQuay 6025174 is intended for compatible Daikin and McQuay heat pumps and HVAC systems requiring an OEM four-way reversing valve coil assembly. Confirm the part number and relevant specifications against the original equipment documentation before selecting a replacement. For exact compatible equipment models, refer to the manufacturer's documentation. Do not assume compatibility based on the manufacturer name alone.

TECHNICAL SPECIFICATIONS:
Product Identification:
Brand: Daikin-McQuay
Part Number: 6025174
Component Type: Four Way Valve Coil Assembly

Write Your Own Review
You're reviewing:Daikin-McQuay 6025174 Four Way Valve Coil Assembly .
Your Rating
Customer Questions
What maintenance is required for the Daikin-McQuay 6025174 Valve Coil Assembly?

Inspect the coil assembly regularly for corrosion, wear, or loose connections. Ensure electrical terminals are secure and free from debris. Clean the surrounding area to prevent overheating. Proper care maintains efficient valve operation and prevents system malfunctions.

What are common issues with the Daikin-McQuay 6025174 Valve Coil Assembly?

  • Failure to actuate or respond.
  • Overheating due to dirt or poor ventilation.
  • Electrical connection problems.
  • Corrosion or insulation breakdown.

What primary function does the Daikin-McQuay 6025174 coil assembly serve?

The coil generates the electromagnetic force needed to actuate the pilot valve within a four-way reversing valve, enabling heat pumps to switch refrigerant flow directions.

When should the Daikin-McQuay 6025174 four-way valve coil be replaced?

Replacement is required when electrical testing indicates an open or shorted coil winding, or when visual inspection reveals cracked or heat-damaged casing insulation.

Does changing the 6025174 coil assembly require opening the refrigerant circuit?

No, the coil assembly mounts externally over the four-way valve pilot stem and can be safely replaced without opening sealed copper refrigerant lines.

How does the 6025174 coil assembly interact with the system thermostat?

When the thermostat calls for a mode change, it sends or cuts electrical voltage to the coil, signaling the assembly to shift the reversing valve pilot mechanism accordingly.

What steps should be completed prior to replacing a reversing valve coil assembly?

Verify the part number in official equipment manuals, disconnect main power to the HVAC system, and check 24V control circuit voltage before removing the retaining clip.

Installation Steps

Step 1: Turn off power to the system and relieve any pressure in the lines.

Step 2: Locate the existing four-way valve coil and disconnect wiring carefully.

Step 3: Remove the old coil from the valve body.

Step 4: Position the new coil assembly onto the valve and secure it.

Step 5: Reconnect the electrical wiring according to original configuration.

Step 6: Restore power and test the system to ensure proper operation.