NTI Boiler 6008299402 Combustion Blower EBM TI/LX 400
Specifications
- Type: Blower
- Model: EBM TI/LX 400
Loyalty ProgramStep 1: Turn off power and gas wait for unit to cool.
Step 2: Remove front panel and disconnect blower wiring harness and mounting screws.
Step 3: Carefully remove old combustion blower.
Step 4: Install new blower, ensuring gasket seal alignment and secure fasteners.
Step 5: Reconnect wiring, restore power and gas, then test ignition and check for abnormal noise or leaks