Taco 5401-2 Direct Mount Operator 46°F/82°F

Special Price $75.61 Regular Price $86.96
In stock
SKU
5401-2
The Taco 5401-2 Direct Mount Operator is an essential actuator that is suitable for controlling fan coils, VAV boxes, unit ventilators and other HVAC systems. This operates within a temperature range of 46°F to 82°F and provides smooth modulation or two-position control with valves. It has no linkage or brackets which makes it easy to install because it is a direct mount. Designed for great use in energy-saving HVAC systems improves efficiency and comfort by precisely controlling flow. These attributes include high durability, low energy use non-need for frequent maintenance, that the product can be wisely used in Building Automation and Zone Control systems.
Manufacturer:
https://www.partshnc.com/media/catalog/product/5/4/5401-2.jpg

Specifications

  • Type: Direct Mount
  • Temperature: 46°F-82°F
Manufacturer Name: Taco
Product Number: 5401-2
OEM Part Number: 5401-2
Product Description: 46/82F Direct Mount Operator
Weight:0.3lbs/136.08g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Taco 5401-2 Direct Mount Operator 46°F/82°F
Your Rating
Customer Questions
What maintenance is required for the Taco 5401-2 Direct Mount Operator?

Inspect the operator for secure mounting and proper electrical connections, ensuring no loose wiring or corrosion affecting performance. Verify actuator movement across range and keep components clean, ensuring safe power isolation during service for accurate operation.

What are common issues with the Taco 5401-2 Direct Mount Operator?

  • Actuator may stick or fail to move smoothly due to internal wear or mechanical obstruction.
  • Temperature response inconsistency causing improper system operation.
  • Electrical connection faults or wiring issues leading to intermittent control failure.

Installation Steps

Step 1: Shut off the heating system and allow the piping and valve assembly to cool.

Step 2: Remove the existing operator from the thermostatic valve body.

Step 3: Inspect and clean the valve connection surface.

Step 4: Align the new direct mount operator with the valve and secure it in place.

Step 5: Adjust the temperature setting within the desired range.

Step 6: Restore system operation and verify proper valve response and temperature control.