Facebook Pixel

Rheem-Ruud 51-102728-14 1/3HP ECM Outdoor Motor 240V

Special Price $500.61 Regular Price $555.68
In stock
SKU
51-102728-14
The Rheem-Ruud 51-102728-14 1/3HP ECM motor in the outdoor is a highly efficient part for outdoor HVAC systems. It utilizes advanced ECM technology and that makes it superior in performance as well as energy savings compared to conventional AC motors. The unit operates at 240V with an output power of 1/3 HP and drives efficient condenser fans with air conditioning and heat pump systems. ECM motors have precise speed control resulting in optimized airflow and productivity of the entire system hence lower amounts of energy consumed which in turn reduces the running costs. Additionally, its solid construction ensures durability under extreme weather conditions.
Manufacturer:
https://www.partshnc.com/media/catalog/product/5/1/51-102728-14-rheem-ruud_partshnc.jpg

Specifications

  • Voltage: 240V
  • Horsepower: 1/3HP
  • Weight: 12.3lbs
  • Type: ECM
  • Type: Outdoor Motor
  • Speed: Variable Speed
  • Frequency: 60 Hz
Manufacturer Name: Rheem-Ruud
Product Number: 51-102728-14
OEM Part Number: 51-102728-14
Product Description: 1/3Hp 240V Ecm Outdoor Motor
Weight:12.3lbs/5579.18g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Rheem-Ruud 51-102728-14 1/3HP ECM Outdoor Motor 240V
Your Rating
Customer Questions
What maintenance is required for the Rheem-Ruud 51-102728-14 Outdoor Motor?

Keep the motor clean and free of dust and debris. Inspect electrical connections and tighten any loose terminals periodically. Ensure proper lubrication of bearings if applicable and check mounting stability.

What are common issues with the Rheem-Ruud 51-102728-14 Outdoor Motor?

  • Reduced airflow due to worn bearings or dust buildup in motor housing.
  • Intermittent operation or failure to start caused by electrical connection faults.
  • Overheating from excessive load or inadequate ventilation.
  • Unusual noise or vibration indicating internal wear.

Installation Steps

Step 1: Turn off power at the breaker and confirm zero voltage.

Step 2: Remove the condenser top/grille and disconnect motor wiring, labeling connections.

Step 3: Loosen the fan blade and remove the old motor from the mounting bracket.

Step 4: Install the new motor, ensuring proper orientation and secure mounting.

Step 5: Reattach the fan blade and reconnect wiring per the diagram.

Step 6: Reassemble unit, restore power, and test for correct rotation and smooth operation.