Facebook Pixel

Amana-Goodman 50N6229V-ZAKMS 208-230V1Ph R410A 2.5Ton Comp

Special Price $561.48 Regular Price $623.25
In stock
SKU
50N6229V-ZAKMS

The Amana-Goodman 50N6229V-ZAKMS is a 2.5-ton compressor that powers your air conditioning system. It runs on single-phase power at 208–230 volts and uses R410A refrigerant. To keep your house cool and pleasant, this workhorse continuously pumps refrigerant, absorbing heat indoors and releasing it outdoors. It easily attaches to a variety of HVAC systems, such as packaged units and split air conditioners. Its robust construction guarantees long-lasting performance, and its efficient operation saves energy costs. By upgrading this Amana-Goodman compressor, you can make sure that your HVAC system operates effectively and smoothly for many years to come, providing dependable cooling. This vital part is frequently incorporated into heat pumps and air conditioners, and it is essential to preserving cozy interior temperatures.

Manufacturer:
https://www.partshnc.com/media/catalog/product/5/0/50n6229v-zakms.jpg
Manufacturer Name: Amana-Goodman
Product Number: 50N6229V-ZAKMS
OEM Part Number: 50N6229V-ZAKMS
Product Description: 208-230V1ph R410a 2.5Ton Comp
Weight:42.14lbs/19114.37g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Amana-Goodman 50N6229V-ZAKMS 208-230V1Ph R410A 2.5Ton Comp
Your Rating
Customer Questions
What maintenance is required for the Amana-Goodman 50N6229V-ZAKMS Compressor?

Regularly inspect the compressor for dust, oil leaks, or loose electrical connections. Ensure proper refrigerant levels and clean surrounding areas for airflow. Always turn off power before servicing to prevent injury or equipment damage.

What are common issues with the Amana-Goodman 50N6229V-ZAKMS Compressor?

  • Failure to start.
  • Unusual noise during operation.
  • Reduced cooling performance.
  • Overheating of the unit.

Installation Steps

Step1: Turn off power and recover refrigerant before starting.

Step2: Remove old compressor, noting line and electrical connections.

Step3: Clean mounting area and verify proper fit.

Step4: Set the new compressor in place and secure it.

Step5: Reconnect electrical terminals.

Step6: Evacuate system, recharge with R410A, then test operation safely.