Facebook Pixel

Danfoss 067L5956 4Ton Thermal Expansion Valve (TXV) Kit 3/8" TR6 R-410A

Special Price $85.11 Regular Price $97.88
In stock
SKU
067L5956
The Danfoss 067L5956 4-Ton Thermal Expansion Valve Kit 3/8” TR6 R-410A is complete solution for the refrigerant flow regulation for the HVAC systems, which provides better cooling at the nominal conditions. This thermal expansion valve set is made of brass with copper terminals for the high reliability. It is intended to be used with R-410A refrigerant systems for HVAC units with The device works optimally and can work effectively within the range of 15°F – 60°F. It is able to manage the flow of refrigerant in a manner that will meet the cooling needs of the system. It is light, and can be used in many kinds of HVAC equipment with R-410A refrigerant.
Manufacturer:
https://www.partshnc.com/media/catalog/product/0/6/067l5956.jpg

Specifications

  • Type: Thermal Expansion Valve
  • Body material: Brass
  • Connection material: Copper
  • Inlet Size: 3/8"
  • Capacity: 4Ton
  • Refrigerant: R-410A
  • Type: TR 6
  • Temperature Range: 15°F-60°F
  • Weight: 1.34lbs
Manufacturer Name: Danfoss
Product Number: 067L5956
OEM Part Number: 067L5956
Product Description: 3/8"Tr6 Txv R-410A 4Ton W/Kit
Weight:1.34lbs/607.81g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Danfoss 067L5956 4Ton Thermal Expansion Valve (TXV) Kit 3/8" TR6 R-410A
Your Rating
Customer Questions
What maintenance is required for the Danfoss 067L5956 Thermal Expansion Valve Kit?

Regularly inspect the valve for leaks and ensure connections are tight. Clean any debris around the inlet and outlet ports. Verify proper refrigerant flow and monitor system pressure. Follow safety protocols to avoid refrigerant exposure during checks.

What are common issues with the Danfoss 067L5956 Thermal Expansion Valve Kit?

  • Inconsistent refrigerant flow.
  • Valve sticking or clogging.
  • Pressure fluctuations in the system.
  • Reduced cooling efficiency.
  • Unusual hissing or noise from the valve.

Installation Steps

Step 1: Turn off power and safely recover refrigerant from the system.

Step 2: Disconnect the old TXV and inspect piping for debris or damage.

Step 3: Position the new TXV according to the flow direction markings.

Step 4: Secure the sensing bulb to the suction line with proper placement.

Step 5: Tighten all fittings and insulate connections as needed.

Step 6: Evacuate and recharge the system with then test for proper cooling performance.