Facebook Pixel

Carrier 345585-75111 Ventor Induced Motor Assemby

Special Price $498.38 Regular Price $623.89
In stock
SKU
345585-75111

The Carrier 345585-75111 Draft Inducer Ventor Motor Assembly is a vital component in your HVAC system responsible for safe and efficient operation. It's essentially an electric motor directly connected to a fan blade assembly. When energized, the motor spins the fan blade at high speed (1050 RPM in this case), creating negative pressure within the system. This negative pressure acts like a vacuum, drawing combustion gases out of the furnace or boiler and venting them safely outdoors. It also helps pull fresh air into the burner for proper combustion. This draft inducer assembly is typically found in Carrier furnaces and can be used with either 208V or 230V electrical service. It's a powerful unit with a ½ horsepower motor, making it suitable for most residential applications. With a weight of 10.85 lbs, it's a relatively compact and manageable component for qualified technicians. By ensuring proper venting and combustion air intake, this draft inducer assembly contributes to a safe, efficient, and reliable operation of your Carrier HVAC equipment.

Manufacturer:
https://www.partshnc.com/media/catalog/product/3/4/345585-75111_carrier_partshnc_1.jpg

Specifications

  • Voltage/Electrical: 208-230V
  • RPM (Revolutions Per Minute): 1050 RPM
  • Horsepower(HP): 1/2HP
  • Frequency: 50Hz
  • Weight: 10.85lbs
Manufacturer Name: Carrier
Product Number: 345585-75111
OEM Part Number: 345585-75111
Product Description: Ventor Motor Assemby Idm
Weight:8.07lbs/3660.49g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Carrier 345585-75111 Ventor Induced Motor Assemby
Your Rating
Customer Questions
What maintenance is required for the Carrier 345585-75111 Ventor Induced Motor Assemby?

Perform regular inspection of wiring, bearings, and mounting to ensure stable operation. Clean dust and debris from the motor housing and blower assembly to maintain airflow efficiency. Ensure electrical connections are tight and follow safety precautions before servicing.

What are common issues with the Carrier 345585-75111 Ventor Induced Motor Assemby?

  • Motor overheating due to dust buildup or restricted airflow.
  • Bearing wear causing noise or vibration.
  • Electrical connection faults leading to intermittent operation.
  • Reduced airflow or failure to start.
  • Excessive noise from unbalanced fan assembly.

Installation Steps

Step 1: Turn off power and shut gas supply; allow unit to cool completely before servicing.

Step 2: Remove access panel and disconnect wiring harness, labeling each connector carefully.

Step 3: Detach old induced draft motor assembly from housing without damaging gasket.

Step 4: Install new motor, secure mounting screws firmly in place.

Step 5: Reconnect wiring, ensure tight connections and restore panel securely.

Step 6: Restore power and test operation for proper venting and airflow.