Facebook Pixel

NAVIEN 30024866A Flow Sensor

Special Price $49.92 Regular Price $64.90
In stock
SKU
30024866A
The Navien Tankless Water Heaters 30024866A is a Flow Sensor, manufactured solely to measure water flow and is the vigilant eye of the water heater. It is made of rigid PVC and stainless steel and its fixture is included in the plumbing system of the heater to determine the amounts and speeds of the water that passes through it. The control board of the heater receives this information after that. Effective heating of water by the sensor helps save energy through flow measurement of water and the heater will turn on and provide hot water when required.
https://www.partshnc.com/media/catalog/product/3/0/30024866a.jpg

Specifications

  • Type: Flow Sensor
  • Compatibility: Navien Tankless Water Heaters
  • Material: Stainless Steel & PVC
  • Temperature: -4°F-212°F
  • Voltage: 24V AC/DC
  • Weight: 0.24lbs
Monitors water movement within the water circuit of a tankless water heater during hot-water demand. Designed for Navien tankless water heaters, the NAVIEN TANKLESS WATER HEATERS 30024866A Flow Sensor provides the flow-sensing component used within the equipment. Its application is centered on detecting water movement as part of tankless water-heating operation.

Water Flow Detection:
Water movement through the heater provides the operating condition that the flow sensor detects. The sensing component responds to water flow within the tankless water heater and provides the associated flow information for equipment operation. This allows the water heater to recognize when water is moving through its water circuit.

Water Heating Flow Sensing:
Within a tankless water heater, water flow occurs as hot-water demand moves water through the equipment. The flow sensor monitors this movement as part of the water-heating cycle. Its sensing activity is directly associated with recognizing water flow while the tankless water heater is operating.

Replacement Guidelines:
Consider replacing the flow sensor when the tankless water heater no longer consistently recognizes water movement or when the existing sensor is no longer providing the expected flow-sensing response. Verify the exact Navien tankless water heater model and the existing part number before selecting 30024866A to ensure the part corresponds with the equipment.

Common Signs of Wear:

  • Inconsistent water-flow detection
  • Failure to recognize water movement
  • Intermittent flow-sensing response
  • Flow-related operating interruptions
  • Flow-sensing fault indications

Equipment Compatibility:
NAVIEN TANKLESS WATER HEATERS 30024866A Flow Sensor is intended for Navien tankless water heaters where this flow sensor is specified. The applicable equipment model should be verified against the manufacturer's parts information before selecting this component.

Technical Specifications:
Brand: Navien
Equipment Type: Tankless Water Heaters
Component Type: Flow Sensor
Part Number: 30024866A

Write Your Own Review
You're reviewing:NAVIEN 30024866A Flow Sensor
Your Rating
Customer Questions
Are flow sensors compatible with all tankless water heaters and HVAC systems?

Compatibility can vary between models and manufacturers. It's important to check with your water heater's manufacturer or the flow sensor's specifications to ensure compatibility.

Do flow sensors come with remote monitoring capabilities for convenient control and oversight?

Some models of flow sensors are equipped with remote monitoring capabilities, allowing users to adjust settings and monitor the water heater's performance from a distance. Check the product specifications for details.

Can I install multiple flow sensors in parallel to monitor different water lines or zones in my HVAC system?

Yes, multiple flow sensors can be installed in parallel to monitor various water lines or zones. This can provide more granular control and monitoring of your HVAC system.

What maintenance is required for the Navien Tankless Water Heaters 30024866A Flow Sensor?

Inspect the flow sensor regularly for mineral buildup and debris that may affect accurate water flow detection. Clean and descale the sensor during routine tankless heater maintenance to maintain proper performance. Check electrical connections for tightness and corrosion to ensure reliable signal transmission. Always disconnect power and shut off water supply before servicing for safety.

What are common issues with the Navien Tankless Water Heaters 30024866A Flow Sensor?

  • Inaccurate flow readings.
  • Intermittent or failed sensor signals.
  • Leaks at connection points.
  • System errors triggered by faulty readings.

What is a flow sensor used for in a Navien tankless water heater?

A flow sensor monitors water movement through the tankless water heater and provides flow-related information during water-heating operation.

What does the 30024866A Flow Sensor detect during water-heating operation?

It detects water movement through the water circuit, allowing the equipment to recognize flow during the operating cycle.

How does a flow sensor support the tankless water heater operating cycle?

Flow-sensing information allows the equipment to recognize water movement associated with hot-water demand and coordinate the applicable operating sequence.

What signs can indicate a flow sensor may need attention?

Inconsistent or intermittent recognition of water movement can indicate an issue with the flow-sensing component and may warrant evaluation.

Which Navien tankless water heaters use this flow sensor?

The flow sensor is associated with Navien tankless water heaters, and the exact equipment model should be verified against the applicable part information before selection.

Installation Steps

Step1: Turn off power and water supply, then relieve system pressure before starting.

Step2: Open the access panel on the Navien tankless heater.

Step3: Disconnect wiring and remove the old flow sensor from the line.

Step4: Install the new flow sensor, reconnect wiring, restore water and power, and test for proper flow detection.